FVC-3000肺活量計(jì)檢測(cè)儀 |
聯(lián)系人:曾工 (先生) | 手機(jī):15361860065 |
電話: |
傳真: |
郵箱:medicalqc@163.com | 地址:深圳市福田區(qū)沙頭角街道泰然四路天安數(shù)碼時(shí)代大廈A座202B |
FVC-3000肺活量計(jì)檢測(cè)儀,FVC-3000肺活量儀測(cè)定儀 空氣“流量”是診斷當(dāng)今兩種最主要的呼吸系統(tǒng)疾病的決定因素。哮喘和COPD。但是,標(biāo)準(zhǔn)的肺活量測(cè)定儀校準(zhǔn)注射器只能準(zhǔn)確地驗(yàn)證其體積!認(rèn)識(shí)到這一點(diǎn),美國胸科學(xué)會(huì)和社會(huì)保障殘疾標(biāo)準(zhǔn)現(xiàn)在建議通過以三種不同的速率改變標(biāo)準(zhǔn)的3升容量注射器的注射時(shí)間來檢查肺量計(jì)線性和流速準(zhǔn)確性。0.5秒,6秒,介于兩者之間。盡管這是對(duì)先前建議的改進(jìn),但這是一種不精確且耗時(shí)的方法,需要秒表。結(jié)果,很少有人遵循這些建議。 FVC-3000肺活量儀測(cè)定儀由美國Jones生產(chǎn)與研發(fā)! FVC-3000肺活量計(jì)檢測(cè)儀,FVC-3000肺活量儀測(cè)定儀 不僅可以驗(yàn)證FVC參數(shù),還可以驗(yàn)證FEV1,F(xiàn)EF 25-75,PEFR和瞬時(shí)呼氣流速(FEF25,F(xiàn)EF50和FEF75)以及FIVC,F(xiàn)在,您可以在1.5到3升的體積范圍內(nèi)以1.5毫升的數(shù)字增量從零到每秒12升驗(yàn)證您的肺功能設(shè)備的流速精度! 單獨(dú)手工制作,達(dá)到最高標(biāo)準(zhǔn) 由9伏電池供電,提供無線,易于使用的設(shè)計(jì) 大型LCD屏幕顯示FVC,F(xiàn)EV1,PEFR,F(xiàn)EF25,F(xiàn)EF50,F(xiàn)EF75,F(xiàn)EF25-75和FIVC 由高品質(zhì)304不銹鋼制成,并進(jìn)行透明涂層處理,以實(shí)現(xiàn)最大的一致性和耐用性 錐形鼻錐可適應(yīng)最廣泛的配件,從1.0“到1.5” 注射腳可確保穩(wěn)定準(zhǔn)確的操作 體積精度為0.5%或15ml,符合所有公認(rèn)的標(biāo)準(zhǔn) 尺寸:4.25英寸(寬)x 26英寸(長) 重量:6.0磅 ![]() Air “flow” is the determining factor in the diagnosis of today’s two most predominant respiratory diseases; asthma and COPD. Yet, standard spirometry calibration syringes can only accurately validate for volume! Recognizing this, the American Thoracic Society and the Social Security Disability standards now recommend checking spirometric linearity and flow rate accuracy by varying injection times of a standard 3-liter volumetric syringe at three different rates; 0.5 seconds, 6 seconds, and somewhere in between. Although this is an improvement over previous recommendations, it is an inaccurate and time-consuming approach requiring a stopwatch. As a consequence, very few people follow these recommendations. The digital Flow-Volume Calibrator® surpasses these requirements by providing the ability to validate not only the FVC parameter, but also the FEV1, FEF 25-75, PEFR and instantaneous expiratory flow rates (FEF25, FEF50, and FEF75), as well as the FIVC. You can now verify the flow rate accuracy of your pulmonary function device from zero to twelve liters per second anywhere in the volumetric range of zero to three liters in digital increments of 1.5 milliliters!
|
版權(quán)聲明:以上所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé)。機(jī)電之家對(duì)此不承擔(dān)任何責(zé)任。 友情提醒:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。 |
機(jī)電之家網(wǎng) - 機(jī)電行業(yè)權(quán)威網(wǎng)絡(luò)宣傳媒體
關(guān)于我們 | 聯(lián)系我們 | 廣告合作 | 付款方式 | 使用幫助 | 會(huì)員助手 | 免費(fèi)鏈接Copyright 2025 jdzj.com All Rights Reserved??技術(shù)支持:機(jī)電之家 服務(wù)熱線:0571-87774297
網(wǎng)站經(jīng)營許可證:浙B2-20080178