應(yīng)急燈澳洲AS2293.3:2018版本更新了什么內(nèi)容 |
聯(lián)系人:曾釗銅 (先生) | 手機(jī):13726907603 |
電話: |
傳真: |
郵箱:bronze.zeng@lcs-cert.com | 地址:廣東省中山市古鎮(zhèn)鎮(zhèn)新興大道東15號(hào)華星家居建材城14樓1403 |
應(yīng)急燈的產(chǎn)品進(jìn)入澳洲市場(chǎng)的能效測(cè)試。進(jìn)入澳洲市場(chǎng)的應(yīng)急燈產(chǎn)品,現(xiàn)在大多數(shù)買家還會(huì)要求供應(yīng)商提供AS2293.3的測(cè)試報(bào)告。 一、測(cè)試標(biāo)準(zhǔn)及內(nèi)容 1.測(cè)試標(biāo)準(zhǔn): AS 2293 Emergency escape lighting and exit signs for buildings AS 2293.3—2005 Part 3: Emergency escape luminaires and exit signs (應(yīng)急逃生燈具和出口標(biāo)志)測(cè)試標(biāo)準(zhǔn) AS 2293.1—2005 Part 1: System design, installation and operation (系統(tǒng)的設(shè)計(jì)、安裝和運(yùn)行) AS/NZS 2293.2:1995 Part 2: Inspection and maintenance (檢查和維護(hù)) 2.測(cè)試內(nèi)容: AS2293.3的測(cè)試項(xiàng)目為應(yīng)急照明等級(jí)、照明啟動(dòng)(冷熱啟動(dòng))、顏色與亮度、電池系統(tǒng)高低溫充放電測(cè)試,與其他一些小的測(cè)試。 應(yīng)急照明等級(jí): 這個(gè)測(cè)試客戶需求高,通常澳洲買家都會(huì)要求產(chǎn)品資料中標(biāo)出應(yīng)急照明等級(jí)。因?yàn)閼?yīng)急照明等級(jí)對(duì)于產(chǎn)品的安裝非常重要,在AS2293.1里面安裝設(shè)計(jì)需要用到,通過這個(gè)等級(jí)能有效的計(jì)算出產(chǎn)品安裝高度與產(chǎn)品安裝間距(推算出這個(gè)房子需要安裝多少個(gè)這種應(yīng)急燈),從而達(dá)到建筑上對(duì)應(yīng)急燈有效的利用和安裝設(shè)計(jì)。應(yīng)急照明等級(jí)是根據(jù)我們的測(cè)試結(jié)果,通過計(jì)算來進(jìn)行判定。 二、測(cè)試流程 客戶提供產(chǎn)品基本信息(系列產(chǎn)品提供差異表)與資料(電池規(guī)格書)及符合數(shù)量要求的樣品。 LCS進(jìn)行開案。開案時(shí)請(qǐng)注意,如果是單項(xiàng)測(cè)試,需要備注是哪個(gè)測(cè)試項(xiàng)目。 然后工程受理項(xiàng)目,安排測(cè)試,完成報(bào)告 AS2293.3報(bào)告不需要注冊(cè)。因此提交報(bào)告即完成項(xiàng)目。 三、周期 單項(xiàng): 光學(xué)性能: 應(yīng)急照明等級(jí)需要3個(gè)工作日一款 照明啟動(dòng)需要3個(gè)工作日一款 顏色與亮度(僅對(duì)出口標(biāo)志產(chǎn)品)需要5-7個(gè)工作日一款 電池系統(tǒng)性能: 高低溫充放電測(cè)試需要10-15工作日一款 全項(xiàng)目: 主測(cè)產(chǎn)品,一款需要15-25個(gè)工作日(出口標(biāo)志的測(cè)試多一個(gè)項(xiàng)目,周期會(huì)相對(duì)長(zhǎng)一些)。 系列測(cè)試,如果是增加光學(xué)性能測(cè)試,可與主測(cè)產(chǎn)品同步,無需增加周期,如果是增加電池系統(tǒng)能效測(cè)試,需要增加10-15個(gè)工作日。 以上項(xiàng)目如需出報(bào)告要增加2個(gè)工作日。 四、具體報(bào)價(jià)和樣品準(zhǔn)備請(qǐng)聯(lián)系立訊曾先生 AS2293.3 從2005升級(jí)到2018版本了,具體升級(jí)的內(nèi)容, updated from AS 2293.3:2005 to AS/NZS 2293.3:2018. Changes in this edition of the Standard include the following: (a) Introduction of requirements for alternative light sources (i.e. LED) and allowance for the use of emerging battery technologies. (b) Inclusion of New Zealand requirements (for publication as AS/NZS Standard). (c) Updated references to new pictogram standards. (d) Added definition and requirements for dual function exit signs. (e) Replacement of AS 3137 with AS/NZS 60598.2.22. Some details: 1. Dual function exit signs shall firstly comply with all the requirements of the subsequent clauses 3.3 and 3.4 of this Standard in order to then be classified as an emergency luminaire.。 2. All emergency luminaires and exit signs shall comply with AS/NZS 60598.2.22 unless otherwise varied in this Standard. 3. Specific requirements relating to Clauses F6 and F8 of the New Zealand Building Code have been added where it is necessary to alter clauses of this Standard to comply with New Zealand requirements. 4. Additional requirements of marking: a) Where combined or sustained emergency luminaires are used, the location of the emergency light source shall be clearly marked, together with any information necessary to ensure correct light source replacement. b) Designed mounting positions and orientation (related to luminaire position/ safety IP rating, etc.). This information shall be marked on the luminaire to enable identification of the classification for each mounting position. c) For LED exit signs the body shall also be marked with the Projected Light Source Life. 5. Add new clause for particular requirements for centrally supplied emergency luminaires and exit signs。 6. New test requirement: a) Glare limitations: In order to restrict disability glare at higher angles, limitations are applied to the luminous intensity of the luminaire based on the mounting height range in accordance with Table C1. b) Colour temperature and colour rendering index: The colour temperature shall fall with the range from 2500 K to 7000 K. The minimum value of the colour rendering index Ra of the light source utilized in any emergency luminaire shall be greater than 40. c) LED: measure LED Ts temperature and operating current at 40. d) PROJECTION OF LIGHT SOURCE LIFE (LSL) IN LED EXIT SIGNS: LM-80 test report for LED should be provided and LM-80 data for the LED being assessed,based on IES TM-21,calculate the life of LED exit signs. |
版權(quán)聲明:以上所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé)。機(jī)電之家對(duì)此不承擔(dān)任何責(zé)任。 友情提醒:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。 |
機(jī)電之家網(wǎng) - 機(jī)電行業(yè)權(quán)威網(wǎng)絡(luò)宣傳媒體
關(guān)于我們 | 聯(lián)系我們 | 廣告合作 | 付款方式 | 使用幫助 | 會(huì)員助手 | 免費(fèi)鏈接Copyright 2025 jdzj.com All Rights Reserved??技術(shù)支持:機(jī)電之家 服務(wù)熱線:0571-87774297
網(wǎng)站經(jīng)營(yíng)許可證:浙B2-20080178