紀(jì)揚(yáng)科技P-Q Controls E120-1798 SN 130410C優(yōu)勢 |
![]() |
價(jià)格:0 元(人民幣) | 產(chǎn)地:歐美 |
最少起訂量:1件 | 發(fā)貨地:廈門 | |
上架時(shí)間:2019-07-30 13:52:11 | 瀏覽量:149 | |
廈門紀(jì)揚(yáng)科技有限公司
![]() |
||
經(jīng)營模式:生產(chǎn)加工 | 公司類型:私營有限責(zé)任公司 | |
所屬行業(yè):進(jìn)口電機(jī) | 主要客戶:機(jī)械工業(yè) | |
![]() ![]() |
聯(lián)系人:李經(jīng)理 (先生) | 手機(jī):19996826231 |
電話: |
傳真: |
郵箱:624232572@qq.com | 地址:廈門市鼓巖路1號(hào)華論國際大廈1003 |
R101CB2010 Series Fig. C M102CB2, R102CB2 Parallel Fig. D M102CB2010 Parallel Fig. E M100C, R100C Parallel Fig. F M101C, R101C Series SPACE SPACE BARRIER SPACE SPACE SPACE SPACE 100 MAIN LOAD SPACE SPACE SPACE SPACE SPACE LOAD 100 SPACE SPACE SPACE SPACE SPACE SPACE 100 BARRIER SPACE SPACE SPACE 50 BR54U GFI SPACE SPACE BARRIER SPACE SPACE SPACE SPACE 100 20 5-20R2GFC1 SPACE 100 LOAD SPACE SPACE SPACE 100 MAIN Overhead/Underground Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A M101CB2 R101CB21,2 CB2100 100 6 AN 14 x 26 LC88PC 38 1 Y B — R101CB2010 CB2100, CB120 100 5 C M102CB2 R102CB21 CB2100 100 6 D M102CB2010 — CB2100, CB120 100 5 Overhead Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless E M100C R100C CB2100 100 1 AB 9 x 30 LC33N1 24 1 Y F M101C4 R101C CB2100 100 3 AB 9 x 30 LC55N1 25 G M102E R102E3 — 100 5 AB 9 x 30 LC55N1 24 H M100T5 R100T5 CBT2102 100 0 AB 9 x 30 LC32X1 24 I M354C — CB250 100 3 AD 9 x 30 LC55N1 25 Y6 1 Add “LK” suffix after model number for barrel lock model. 2 Add “ETG” suffix after model number for Entergy Utility approved model. 3 Available with neutral, order R102EN. Consult representative/utility for local utility acceptance. 4 Available with copper wire, order M101CC. 5 “Triple-Tap” - 3 load lugs per phase. 6 cULus approved. * Wire Range Table on page 26. GFI 20 SPACE BARRIER SPACE SPACE SPACE SPACE MAIN 100 5-20R2GFC1 Midwest Electric Products Service Equipment 9 Data subject to change without notice. Service Equipment Metered Surface, Side-by-Side, 125 – 150 Amps, 120/240V Surface, 150 Amps, 120/240V Fig. A MS125E Series Fig. D M181CB1, R181CB1 Series Fig. B MS150C, RS150C Series Fig. C MS151C Series SPACE SPACE SPACE SPACE SPACE SPACE LOAD LOAD 150 MAIN BARRIER MAIN 150 LOAD MAIN 150 LOAD SPACE SPACE SPACE SPACE SPACE Overhead/Underground Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A MS125E None 125 2 BC 16 x 17 PC2LC 24 B MS150C RS150C1 CB2150B 150 0 BC 17 x 26 — 41 1 Y C MS151C — CBL2151 150 5 BC 17 x 26 LC55N1 43 1 Add “GP” suffix after model number for Georgia Power Utility approved model. Overhead/Underground Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless D M181CB1 R181CB11 CB4150H 150 4 BG 14 x 28 LCTL + LCBS 34 1 Y 1 Add “GP” suffix after model number for Georgia Power Utility approved model. * Wire Range Table on pages 26-27. Midwest Electric Products Service Equipment 10 Data subject to change without notice. Service Equipment Metered Surface, 200 Amps, 120/240V Fig. A MS250C, RS250C Series Fig. H M281CB1, R281CB1 Series Fig. I M282CB1, R282CB1 Parallel Fig. J M281EB1, R281EB1 Series Fig. K M282EB1, R282EB1 Parallel Fig. B MS251C, RS251C Series Fig. C MS252C Parallel Fig. D MS252E014 Parallel Fig. E MS2453C Parallel Fig. F R256EB1A Parallel Fig. G M208CR2A, R208CR2A Series MAIN 200 LOAD SPACE SPACE SPACE SPACE LOAD LOAD 200 MAIN BARRIER MAIN 200 LOAD SPACE SPACE SPACE SPACE SPACE LOAD LOAD 200 BARRIER SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 200 LOAD SPACE SPACE SPACE SPACE LOAD LOAD SPACE BARRIER LOAD LOAD SPACE BARRIER SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 200 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE BARRIER SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE LOAD BARRIER Side-by-Side, Overhead/Underground Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A MS250C RS250C2 CB2201 200 0 BC 17 x 26 — 41 1 Y B MS251C RS251C CBL2201 200 5 BC 17 x 26 LC55N1 41 C MS252C — LCB2201 200 5 BC 17 x 26 LC55N1 43 D MS252E0141 — — 200 8 BC 14 x 31 LC88X2 39 E MS2453C — CB4200H 200 8 W 14 x 31 LC88X2 38 Overhead/Underground Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless F — R256EB1A3,4,6 — 200 12 — 14 x 26 — 32 1 Y G M208CR2A R208CR2A CB2200B 200 8 AN 14 x 28 LC1212PC 46 H M281CB1 R281CB12,5,6 CB4200H 200 4 BK 14 x 28 LCTNL + LCBS 34 I M282CB17 R282CB15 CB4200H 200 4 BK 14 x 28 LCTL + LCBS 35 J M281EB1 R281EB1 — 200 5 BK 14 x 28 LCTNL + LCBS 33 K M282EB1 R282EB1 — 200 5 BK 14 x 28 LCTL + LCBS 33.2 1 Space for 8-Single Pole Breakers or 200A Main and 4-Single Pole Breakers. 2 Add “GP” suffix after model number for Georgia Power Utility approved model. GP models not available with barrel lock. 3 Available with aluminum bussing and aluminum enclosure - R256EB1018A. 4 Available with galvanized enclosure with neutral installed - R256EB1NA. 5 Available with barrel lock – add “LK” after model number. 6 Add “ETG” suffix after model number for Entergy Utility approved model. 7 Available with copper wire - M282CB1C. * Wire Range Table on pages 26-27. Midwest Electric Products Service Equipment 11 Data subject to change without notice. Service Equipment Metered Surface, 200 Amps, 120/240V Overhead Feed Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A — R200T2 265A6249G1 200 0 AF 14 x 38 — 42 1 Y B M208CR2B010 — CB2200B, CB120 200 7 AN 14 x 38 LC1212PC 50 C M254C — CB2200B, CB250 200 2 S 14 x 38 LC88PC 40 D M280T2 R280T2,4 265A6249G10 200 0 BD 9 x 32 — 32 E M281C1 R281C1 CB4200H 200 4 BK 9 x 30 LCTL + LCBS 26 F M282C1C1 — CB4200H 200 4 BJ 9 x 30 LCTL + LCBS 26 G M285T2,3 — CBT2201N 200 0 BD 9 x 32 — 27 1 Copper wired. 2 “Triple-Tap” – 3 load lugs per phase. 3 225A non-auto switch, no circuit protection. 4 Available with earth burial post – R280TP6HP. * Wire Range Table on pages 26-27. Fig. A R200T Series Fig. G M285T Series Fig. B M208CR2B010 Series Fig. C M254C Series Fig. D M280T, R280T Series Fig. E M281C1, R281C1 Series Fig. F M282C1C Parallel 200 MAIN LOAD NONAUTO 225 MAIN LOAD SPACE SPACE SPACE SPACE SPACE SPACE 20 SPACE 200 MAIN 200 MAIN BARRIER BARRIER GFI 5-20R2GFC1 LOAD SPACE SPACE 200 MAIN 50 BR54U 200 MAIN LOAD SPACE SPACE SPACE SPACE LOAD LOAD 200 MAIN SPACE SPACE SPACE SPACE LOAD LOAD 200 Midwest Electric Products Service Equipment 12 Data subject to change without notice. Service Equipment Unmetered Surface, 100 – 125 Amps, 120/240V Fig. A U101C Series Fig. B U102E Parallel Fig. C U354C Series Fig. D UL412RMW Parallel Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL A U101C CB2100 100 3 Z 9 x 17 LC55N1 15 1 Y B U102E None 100 5 V 9 x 17 LC55N1 15 C U354C CB250 100 3 V 9 x 17 LC55N1 16 Y2 D UL412RMW1 None 125 4/8 6-2/0 7 x 10 425D549P1 7 Y 1 (4) 1" spaces or (8) 1/2" spaces available. 2 cULus approved. * Wire Range Table on page 27. LOAD LINE SPACE SPACE SPACE 100 MAIN LINE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 50 BR54U LINE SPACE SPACE SPACE SPACE Midwest Electric Products Service Equipment 13 Data subject to change without notice. Service Equipment Unmetered Surface, 150 – 200 Amps , 120/240V Fig. A U180C1 Series Fig. E U281C1 Series/Parallel Fig. F U281C1 Series/Parallel Fig. B U181C1 Series/Parallel Fig. C U208C Series Fig. D U280C1 Series/Parallel Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL A U180C1 CB4150H 150 0 AW 9 x 21 LCTL + LCBNS 15 1 Y2 B U181C11 CB4150H 150 4 AX 9 x 21 LCTL + LCBS 21 Y C U208C CB2200B 200 8 AN 14 x 21 LC1212PC 30 D U280C11 CB4200H 200 0 BF 9 x 21 LCTL + LCBNS 18.2 Y2 E U281C11 CB4200H 200 4 BG 9 x 21 LCTL + LCBS 18.7 Y F U281E11 — 200 5 BG 9 x 21 LCTNL + LCBS — 1 Series or parallel wired. 2 cULus approved. * Wire Range Table on pages 26-27. LINE LINE LOAD LOAD 150 MAIN LINE LINE LOAD LOAD 150 MAIN SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE LINE LOAD 200 MAIN LINE LINE LOAD LOAD 200 MAIN LINE LINE LOAD LOAD 200 MAIN SPACE SPACE SPACE SPACE LINE LINE LOAD LOAD SPACE SPACE SPACE SPACE SPACE Midwest Electric Products Service Equipment 14 Data subject to change without notice. Service Equipment All-In-One 400 Amps ? Rated as service equipment (Panelboard No. 67 and Meter Sockets No. 414) ? Units supplied with factory installed main breakers rated 22kAIC where applicable ? Units available with or without load center with 8 circuit models being standard. Other configurations available, consult manufacturer. ? Load centers are provided with copper bus, 22kAIC bus bracing, and 100% neutral terminations. Feed-through lugs provided on load centers with main breakers. ? 320A continuous duty meter socket available in ring type, K-4 bolt on, or ringless (lever bypass) ? All terminals accept copper or aluminum wire for added installation flexibility ? Utility meter socket compartment has barrier from main circuit breakers for utility power protection ? Factory installed flange for easy semi-flush or surface installation ? NEMA 3R weatherproof enclosures ? G90 galvanized steel construction for superior corrosion protection ? Durable polyester powder coat finish resists chipping and fading ? Underground feed only, series wired, 240V single phase, and branch circuits accept combinations up to 200A ? Fifth jaw optional - order Model # MS5MIL ? Line side 1/2" stud termination provided, however, crimp-on/connector lug not provided by Midwest ? Bottom feed only – no hub provision Fig. Model Number Circuit Protection OCP Device Rating (Amps) Amps Spaces (Max. 1") Wire Range* Cabinet Size Hub Opening Load Center Unit Wt. Std Pkg. UL Ring Type Ringless – Lever Bypass 1 2 1 2 A MS45500C — CB2201H CB2201H 200 200 400 — 400 Amps 31 x 33 N — 95 1 Y B MS45508C — CB2201H CB2201H 200 200 400 8 8 Circuits 99 C — RS43308C CB2151H CB2151H 150 150 400 8 8 Circuits 99 D — RS45500C CB2201H CB2201H 200 200 400 — — 95 E — RS45508C CB2201H CB2201H 200 200 400 8 8 Circuits 99 * Wire Range Table on page 27. Fig. A MS45500C CB2201H Fig. B MS45508C CB2201H Fig. C RS43308C CB2151H Fig. E RS43308C CB2201H Fig. D RS45500C CB2201H 200 MAIN 200 MAIN 200 MAIN 200 MAIN SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 150 MAIN 150 MAIN SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 200 MAIN 200 MAIN SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 200 MAIN 200 MAIN Midwest Electric Products Service Equipment 15 Data subject to change without notice. Service Equipment Metered Pedestal, 100 Amps, 120/240V Inline Post Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A M101CP61,2 R101CP6 CB2100 100 3 T2 9PT LC55N1 59 B M354CP6 — CB250 100 3 AS 9PT LC55N1 59 1 Y C — R211CP6 CB2100 100 0 S 9PT PC2LC 53 Back-to-Back Inline Post Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless D M101CB6 R101CB6 CB2100 100 3 T2 9PT LC55N1 82 1 Y E M354CB6 — CB250 100 3 AT 9PT LC55N1 82 Head Post Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless F M101CP6HP3 R101CP6HP CB2100 100 3 S 9HP LC55N1 80 1 Y Back-to-Back Head Post Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless G M101CB6HP R101CB6HP CB2100 100 3 S 9HP LC55N1 110 1 Y H — R255CB6010 CB2200B, CB250, CB120 100 5 S 14PT LC1212PC 101 N 1 Available in Ring Type, pad mount - M101CP4. 2 Available in Ring Type, copper wire - M101CP6C. 3 Available with GFCI duplex receptacle in Ring Type only - M101CP6HP010. * Wire Range Table on pages 26-27. Fig. A M101CP6, R101CP6 Series Fig. G M101CB6HP, R101CB6HP Series Fig. H R255CB6010 Series Fig. B M354CP6 Series Fig. C R211CP6 Series Fig. D M101CB6, R101CB6 Series Fig. E M354CB6 Series Fig. F M101CP6HP, R101CP6HP Series LOAD SPACE SPACE SPACE 100 MAIN LOAD SPACE SPACE SPACE 100 MAIN POST LOAD SPACE SPACE SPACE 100 MAIN POST SPACE SPACE SPACE 50 BR54U 200 MAIN POST 20 50 SPACE SPACE SPACE SPACE SPACE LOAD 200 MAIN 20 50 SPACE SPACE SPACE SPACE SPACE LOAD 5-20R2GFC1 BR54U GFI 5-20R2GFC1 BR54U GFI 100 LOAD LOAD SPACE SPACE SPACE 100 MAIN SPACE SPACE SPACE POST 100 MAIN (2) 14-50R SPACE SPACE SPACE SPACE SPACE SPACE POST 50 50 (2) BR54U LOAD SPACE SPACE SPACE 100 MAIN Midwest Electric Products Service Equipment 16 Data subject to change without notice. Service Equipment Metered Pedestal, 200 Amps, 120/240V Inline and Head Post Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A M208CP6HP R208CP6HP CB2200B 200 8 S 14HP LC1212PC 85 1 Y B M254CP61 — CB2200B, CB250 200 2 S 14PT LC88PC 96 C M255GP61 — CB2200B, CB250, GFI120 200 5 S 14PT LC1212PC 87 D — R2502CP6 CB4200H 200 4 BM 9PT LCTL + LCBS 53 E M281C1P6H2,3,4 R281C1P6H4 CB4200H 200 4 S 6H LCTNL + LCBS 68 F M281E1P6H R281E1P6H — 200 5 S 6H LCTNL + LCBS 67 G M282C1P6H2,3,5 R282C1P6H CB4200H 200 4 S 6H LCTNL + LCBS 69 H M282E1P6H2 R282E1P6H — 200 5 S 6H LCTNL + LCBS 68 I M654CP61 — CB250 200 6 S 14PT LC88PC 85 J M655GP61 — CB250, GFI120 200 9 S 14PT LC1212PC 85 Y6 K — R225CP6010 CB2200B, CB250, CB120 200 5 S 14PT LC1212PC 88 N 1 Rated as Temporary Site Service Equipment. 2 Available with GFCI Receptacle installed – add “010” after model number. 3 Available in Ring Type with stud termination - M281C1S6H and M282C1S6H. 4 Available in Ring Type with stud termination and copper wire - M281C1S6HC and R281C1S6HC. 5 Available in Ring Type with copper wire - M282C1P6HC. 6 cULus approved. * Wire Range Table on page 26-27. Fig. C M255GP6 Series Fig. A M208CP6HP, R208CP6HP Series Fig. H M282E1P6H, R282E1P6H Parallel Fig. I M654CP6 Parallel Fig. J M655GP6 Parallel Fig. K R255CP6010 Parallel Fig. B M254CP6 Series Fig. D R2502CP6 Parallel Fig. E M281C1P6H, R281C1P6H Series Fig. F M281E1P6H, R281E1P6H Series Fig. G M282C1P6H, R282C1P6H Parallel 200 MAIN SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE LOAD 200 MAIN SPACE SPACE LOAD BR54U 50 200 MAIN SPACE SPACE SPACE SPACE SPACE LOAD BR54U 5-20R 20 GFI 50 SPACE SPACE SPACE SPACE 2002 0M0AIN LOAD LOAD SPACE SPACE SPACE SPACE 2002 0M0AIN LOAD LOAD SPACE SPACE SPACE SPACE LOAD LOAD 20S20P 0AMC0AEIN SPACE SPACE SPACE SPACE SPACE LOAD LOAD SPACE SPACE SPACE SPACE SPACE SPACE 50 BR54U SPACE SPACE SPACE SPACE SPACE SPACE POST 5-20R2 BR54U 20 50 GFI SPACE SPACE SPACE SPACE SPACE 5-20R2GFCI BR54U 20 50 LOAD GFI 200 MAIN SPACE SPACE SPACE SPACE SPACE LOAD LOAD Midwest Electric Products Service Equipment 17 Data subject to change without notice. Service Equipment Metered Pedestal, 200 Amps, 120/240V Unmetered Pedestal, 100 – 200 Amps, 120/240V Fig. A M281C1B6H, R281C1B6H Series Fig. E U101CP6 Series Fig. B M281E1B6H, R281E1B6H Series Fig. F U102EP6 Parallel Fig. C M282C1B6H, R282C1B6H Series Fig. D M282E1B6H, R282E1B6H Series SPACE SPACE SPACE SPACE LOAD LOAD 200 MAIN SPACE SPACE SPACE SPACE LOAD LOAD SPACE LOAD LOAD SPACE SPACE SPACE SPACE SP2A0C0E LOAD LOAD SPACE SPACE SPACE SPACE SSPPAACCEE Back-to-Back Head Post Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL Ring Type Ringless A M281C1B6H R281C1B6H CB4200H 200 4 S 6H LCTNL + LCBS 101 1 Y B M281E1B6H R281E1B6H — 200 5 C M282C1B6H R282C1B6H CB4200H 200 4 D M282E1B6H R282E1B6H — 200 5 Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL E U101CP6 CB2100 100 3 T2 9PT LC55N1 46 1 Y F U102EP6 None 100 5 V 9PT LC55N2 Fig. Model Number Circuit Protection Amps Spaces Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL G U208CP6HP CB2200B 200 8 S 14HP LC1212PC 80 H U281C1P6H CB4200H 200 4 S 6H LCTL + LCBS 62 1 Y I U281E1P6H — 200 5 S 6H LCTNL + LCBS 62 * Wire Range Table on pages 27. Fig. G U208CP6HP Series Fig. H U281C1P6H Series Fig. I U281C1P6H Series LINE SPACE SPACE SPACE SPACE SPACE LOAD LINE SPACE SPACE SPACE 100 MAIN SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE LINE LOAD 200 MAIN LINE LINE LOAD LOAD 200 MAIN SPACE SPACE SPACE SPACE LINE LINE LOAD LOAD SPACE SPACE SPACE SPACE SPACE Midwest Electric Products Service Equipment 18 Data subject to change without notice. Service Equipment Metered Lever Bypass Pedestal, Ringless, Surface, 200 Amps, 120/240V Fig. A R208CR2A034 Series Fig. B R281CB1034 Series Fig. C R281EB1034 Series Fig. D R281C1034 Series SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE BARRIER BARRIER 200 MAIN LOAD BARRIER LOAD LOAD SPACE SPACE SPACE SPACE 200 MAIN BARRIER LOAD LOAD SPACE SPACE SPACE SPACE SPACE LOAD LOAD SPACE SPACE SPACE SPACE 200 MAIN Overhead and Underground Feed Fig. Model Number Circuit Protection Amps Spaces Phase Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL A R208CR2A0341 CB2200B 200 8 1 BK 14 x 32 LC1212PC B R281CB1034 CB4200H 200 4 1 BK 14 x 32 LCTL + LCBS 38.4 1 Y C R281EB1034 — 200 4 1 BK 14 x 32 LCTL + LCBS Overhead Feed Fig. Model Number Circuit Protection Amps Spaces Phase Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL D R281C1034 CB4200H 200 4 1 BK 14 x 32 LCTL + LCBS 38.4 1 Y 1 Loop feed lugs installed. * Wire Range Table on page 27. Midwest Electric Products Service Equipment 19 Data subject to change without notice. Service Equipment Metered Lever Bypass Pedestal, Ringless, 200 - 400 Amps, 120/240V Fig. A R281C1P6H034 Series Fig. B R281E1P6H034 Series Fig. C R481C1P6H034 Series Fig. D R460CP6034 Series Fig. E R281C1B6H034 Series Fig. F R281E1B6H034 Series SPACE SPACE SPACE SPACE LOAD LOAD 200 MAIN POST SPACE SPACE SPACE SPACE LOAD LOAD POST SPACE SPACE SPACE SPACE SPACE LOAD LOAD POST 100 MAIN 400 MAIN LOAD LOAD BARRIER SPACE SPACE SPACE SPACE 200 MAIN POST LOAD LOAD BARRIER SPACE SPACE SPACE SPACE POST SPACE Single-Sided Fig. Model Number Circuit Protection Amps Spaces Phase Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL A R281C1P6H034 CB4200H 200 4 1 S 6H034 LCTL + LCBS 83.5 1 Y B R281E1P6H034 — C R481C1P6H0341,3 CB2100 D R460CP60342 TJD422400X2 400 0 BZ 14PT — Back-to-Back Fig. Model Number Circuit Protection Amps Spaces Phase Wire Range* Cabinet Size Load Center Unit Wt. Std Pkg. UL E R281C1B6H034 CB4200H 200 4 1 S 6H034 LCTL + LCBS 114 1 Y F R281E1B6H034 — All lever bypass models include a fifth jaw in the “nine o’clock” position as of 2004. 1 R481C1P6H034 rated at 100A and 10kAIC (100A Breaker, 200A Meter Socket). 2 Model available in green paint - R460CP6034C2. 3 Available in camo green paint – add “G” after model number. * Wire Range Table on page 27. Midwest Electric Products Service Equipment 20 Data subject to change without notice. Service Equipment Technical Data Model Number Replacement Parts Cabinet Size Enclosure Style2 Cabinet Dimensions (inches) Knockout Figure3 Hub kAIC Meter Socket Post Lugs Height (A) Width (B) Depth (C) M100C MSM100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 M100T MSM100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 M101C MSM100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 M101CC MSM100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 M101CB2 MW200M — 14 x 26 D 26-1/4 14-1/4 4-9/16 6 Y 10 M101CB6 MSM100P9 LT100B350 9PT See page 24 Y 10 M101CB6HP MSM100P9 LT200B350 9HP See page 24 N 10 M101CP4 MSM100P9 LT100B250 9PT See page 24 N 10 M101CP6 MSM100P9 LT100S250 9PT See page 24 N 10 M101CP6C MSM100P9 LT200B350 9PT See page 24 N 10 M101CP6HP MSM100P9 LT100S350 9HP See page 24 N 10 M101CP6HP010 MSM100P9 LT200S350 9HP See page 24 N 10 M102CB2 MW200M — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 M102CB2010 MW200M — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 M102E MSM100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 M181CB1 MSMS11 — 14 x 28 D 28-5/8 14-3/8 4-3/4 6 Y 22 M208CP6HP MW200M LT200S350 14HP See page 24 N 10 M208CR2A MW200M — 14 x 28 C 28-5/8 14-3/8 6-3/8 8 Y 10 M208CR2B010 MW200M — 14 x 38 C 38-3/8 14-3/4 6-3/8 8 Y 10 M254C MW200M — 14 x 38 C 38 14-3/4 6-3/8 8 Y 10 M254CP6 MW200M LT200S350 14PT See page 24 N 10 M255GP6 MW200M LT200S350 14PT See page 24 N 10 M280T MW200M — 9 x 32 C 32-1/4 9-3/4 5-11/16 4 Y 10 M281C1 MSMS — 9 x 30 D 30-1/4 9-5/16 4-3/4 12 Y 22 M281C1B6H MSMP LT200B350 6H See page 25 N 22 M281C1P6H MSMP LT200S350 6H See page 25 N 22 M281C1P6H010 MSMP LT200S350 6H See page 25 N 22 M281C1S6H MSMP LT200SS 6H See page 25 N 22 M281C1S6HC MSMP LT200SS 6H See page 25 N 22 M281CB1 MSMS11 — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 M281E1B6H MSMP LT200B350 6H See page 25 N 22 M281E1P6H MSMP LT200S350 6H See page 25 N 22 M281EB1 MSMS11 — 14 x 28 D 30-1/4 9-5/16 4-3/4 13 Y 22 M282C1B6H MSMP LT200B350 6H See page 25 N 22 M282C1C MSMS — 9 x 30 D 30-1/4 9-5/16 4-3/4 12 Y 22 M282C1P6H MSMP LT200S350 6H See page 25 N 22 M282C1P6H010 MSMP LT200S350 6H See page 25 N 22 M282C1P6HC MSMP LT200S350 6H See page 25 N 22 M282C1S6H MSMP LT200SS 6H See page 25 N 22 M282CB1 MSMS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 M282CB1C MSMS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 M282E1B6H MSMP LT200B350 6H See page 25 N 22 M282E1P6H MSMP LT200S350 6H See page 25 N 22 M282E1P6H010 MSMP LT200S350 6H See page 25 N 22 M282EB1 MSMS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 M285T MW200M — 9 x 32 C 32-1/4 9-3/4 5-11/16 4 Y 10 M354C MSM100930 — 9 x 30 C 30 9-3/4 5-3/16 1 Y 10 M354CB6 MSM100P9 LT100B350 9PT See page 24 N 10 M354CP6 MSM100P9 LT100S250 9PT See page 24 N 10 M654CP6 MW200M LT200S350 14PT See page 24 N 10 M655GP6 MW200M LT200S350 14PT See page 24 N 10 MS125E MW200M — 16 x 17 E 17-1/4 16-3/4 5 9 Y 10 MS150C MW200M — 16 x 17 E 17-1/4 16-3/4 5 9 Y 10 MS151C MW200M — 17 x 26 E 17-1/4 16-3/4 5 9 Y 10 MS2453C — — 14 x 31 E 33 16-3/4 6-1/4 17 Y 22 MS250C 198B8601G11 — 16 x 17 E 17-1/4 16-3/4 5 9 Y 10 1 Models prior to April 2004 use MSMS. 2 Enclosure Styles on page 22. 3 Knockout Figures on page 23. Midwest Electric Products Service Equipment 21 Data subject to change without notice. Service Equipment Technical Data Model Number Replacement Parts Cabinet Size Enclosure Style2 Cabinet Dimensions (inches) Knockout Figure3 Hub kAIC Meter Socket Post Lugs Height (A) Width (B) Depth (C) MS251C MW200M — 17 x 26 E 26-1/4 17-1/2 5-1/2 10 Y 10 MS252C MW200M — 17 x 26 E 26-1/4 17-1/2 5-1/2 10 Y 10 MS252E014 MW200M — 14 x 31 E 14-3/4 31-5/16 5-7/8 7B Y 10 MS45500C 265A5264P2 — 31 x 33 E 33-1/10 30-1/2 6-1/10 See page 23 N 22 MS45508C 265A5264P2 — 31 x 33 E 33-1/10 30-1/2 6-1/10 See page 23 N 22 R100C MSR100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 R100T MSR100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 R101C MSR100930 — 9 x 30 C 30 9-3/4 5-3/16 3 Y 10 R101CB2 MW200R — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R101CB2LK MW200R — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R101CB2010 MW200R — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R101CB6 MSR100P9 LT100B250 9PT See page 24 N 10 R101CB6HP MSR100P9 LT200B350 9HP See page 24 N 10 R101CP6 MSR100P9 LT100S250 9PT See page 24 N 10 R101CP6HP MSR100P9 LT200S350 9HP See page 24 N 10 R102CB2 MW200R — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R102CB2LK MW200R — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R102E MSR100930 — 9 x 30 C 29-1/2 9-1/4 5-3/16 1 Y 10 R102EN MSR100930 — 9 x 30 C 29-1/2 9-1/4 5-3/16 1 Y 10 R181CB1 MSRS — 14 x 28 D 28-1/2 14-3/10 4-4/5 6 Y 10 R200T MW200R — 14 x 38 C 38-3/8 14-3/4 6-3/8 8 Y 10 R208CP6HP MW200R LT200S350 14HP See page 24 N 10 R208CR2A MW200R — 14 x 28 C 28-5/8 14-3/4 6-3/8 8 Y (2) 10 R208CR2A034 265A5264P8 — 14 x 28 C 28-5/8 14-3/4 6-3/8 8 Y 10 R211CP6 MSRS — 9PT1 See page 24 N 10 R2502CP6 MSRS — 9PT1 See page 24 N 10 R255CP6010 MSR20014 LT200S350 14PT See page 24 Y 10 R255CB6010 MSR20014 LT200S350 14PT See page 24 Y 10 R256EB1A 198B8601G70 — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R256EB1018A 198B8601G70 — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R256EB1NA 198B8601G70 — 14 x 26 D 26-1/4 14-3/4 4-9/16 6 Y 10 R280T MW200R — 9 x 32 C 32-1/4 9-3/4 5-11/16 4 Y 10 R280TP6HP MW200R LT200S350 9HP See page 24 N 10 R281C1 MSRS — 9 x 30 D 30-1/4 9-5/16 4-3/4 12 Y 22 R281C1034 265A5264P8 — 14 x 32 D 32-1/2 14-1/2 5-7/16 15 Y 22 R281C1B6H MSRP LT200B350 6H See page 25 N 22 R281C1B6H034 265A5264P8 LT200B350 6H034 See page 25 N 22 R281C1P6H MSRP LT200S350 6H See page 25 N 22 R281C1P6H034 265A5264P8 LT200S350 6H034 See page 25 N 22 R281C1S6HC MSRP LT200SS 6H See page 25 N 22 R281CB1 MSRS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R281CB1034 265A5264P8 — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R281CB1LK MSRS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R281E1B6H MSRP LT200B350 6H See page 25 N 22 R281E1B6H034 265A5264P8 LT200B350 6H034 See page 25 N 22 R281E1P6H MSRP LT200S350 6H See page 25 N 22 R281E1P6H034 265A5264P8 LT200S350 6H034 See page 25 N 22 R281EB1 MSRS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R281EB1034 265A5264P8 — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R282C1B6H MSRP LT200B350 6H See page 25 N 22 R282C1P6H MSRP LT200S350 6H See page 25 N 22 R282CB1 MSRS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R282CB1LK MSRS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R282E1B6H MSRP LT200B350 6H See page 25 N 22 R282E1P6H MSRP LT200S350 6H See page 25 N 22 1 Not all models listed. Contact local representative for other models and details. 2 Enclosure Styles on page 22. 3 Knockout Figures on page 23. Midwest Electric Products Service Equipment 22 Data subject to change without notice. Service Equipment Technical Data Cabinet Dimensions Model Number Replacement Parts Cabinet Size Enclosure Style1 Cabinet Dimensions (inches) Knockout Figure2 Hub kAIC Meter Socket Post Lugs Height (A) Width (B) Depth (C) R282EB1 MSRS — 14 x 28 D 28-5/8 14-3/8 4-3/4 13 Y 22 R460CP6034 265A5264P10 — 14PT See page 24 N 22 R481C1P6H034 265A5264P8 LT200S350 6H034 See page 25 N 22 RS150C MW200R — 17 x 26 E 26-1/4 17-1/2 5-1/2 10 Y 10 RS250C MW200R — 17 x 26 E 26-1/4 17-1/2 5-1/2 10 Y 10 RS251C MW200R — 17 x 26 E 26-1/4 17-1/2 5-1/2 10 Y 10 RS43308C 265A5264P10 — 31 x 33 E 33-1/10 30-1/2 6-1/10 See page 23 N 22 RS45500C 265A5264P10 — 31 x 33 E 33-1/10 30-1/2 6-1/10 See page 23 N 22 RS45508C 265A5264P10 — 31 x 33 E 33-1/10 30-1/2 6-1/10 See page 23 N 22 U101C — — 9 x 17 B 17-3/8 9-3/4 5-3/16 3 Y 10 U101CP6 — LT100S250 9PT See page 24 N 10 U102E — — 9 x 17 B 17-3/8 9-3/4 5-3/16 3 Y 10 U102EP6 — LT100S250 9PT See page 24 N 10 U180C1 — — 9 x 21 A 21-3/4 9-5/16 4-3/4 11 Y 22 U181C1 — — 9 x 21 A 21-3/4 9-5/16 4-3/4 11 Y 22 U208C — — 14 x 21 B 21-3/8 14-3/4 6-7/16 5 Y 10 U208CP6HP — LT200S350 14HP See page 24 N 10 U280C1 — — 9 x 21 A 21-3/4 9-5/16 4-3/4 11 Y 22 U281C1 — — 9 x 21 A 21-3/4 9-5/16 4-3/4 11 Y 22 U281C1P6H — LT200S350 6H See page 25 Y 22 U281E1 — — 9 x 21 A 21-3/4 9-5/16 4-3/4 11 Y 22 U281E1P6H — LT200S350 6H See page 25 Y 22 U354C — — 9 x 17 B 17-3/8 9-3/4 5-3/16 1 Y 10 UL412RMW — — 7 x 10 A 10 7-1/4 4 2 Y 10 1 Enclosure Styles shown below. 2 Knockout Figures on page 23. Fig. A Fig. B Fig. C Fig. D Fig. E A B C A B C A B C A B C A B C Midwest Electric Products Service Equipment 23 Data subject to change without notice. Service Equipment Knockout Congurations * Knockouts shown for size not for exact positions. Fig. 1 Fig. 5 Fig. 8 Fig. 11 Fig. 15 Fig. 16 Fig. 3 Fig. 17 Fig. 9 Fig. 13 Fig. 2 Fig. 6 Fig. 8A Fig. 12 Fig. 4 Fig. 7B Fig. 10 B B G G G H G G D C C C C C Q C A E D D D D C Q C A E N N X N C A G N N N N A A A F B H B G G R R F F F F F F F F F F F F L L Y L P F H F Y P G G N N N N X F U X F V G G N N N Y X X F D D D C A E Q C Z Z N N X N N X G C A G S U S F L X X X A A V A G G A G A A L G L Knockout Key A = 1-1/2", 2", 2-1/2" B = 1", 1-1/4", 1-1/2" C = 1-1/4", 1-1/2", 2" D = 3/4", 1", 1-1/4" E = 3/4" F = 1/2" G = 1/2", 3/4", 1" H = 9/32" L = 1/2", 3/4" N = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2" P = 1-1/4", 1-1/2", 2", 2-1/2" Q = 1" S = 1/2", 3/4", 1", 1-1/4", 1-1/2" T = 3-1/2", 4" U = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2", 3" V = 3/4", 1", 1-1/4", 1-1/2" X = 1/2", 3/4", 1-1/4", 1-1/2", 2", 2-1/2" Y = 1-1/4", 1-1/2", 2", 2-1/2", 3" Z = 2-1/2", 3", 3-1/2", 4" A T T Z Z V A V V N N X L G F L L L L L L L L L L X Midwest Electric Products Service Equipment 24 Data subject to change without notice. Service Equipment Single Head Post Single Head Post Single Head Post Double Head Post (Back-to-Back) Double Head Post (Back-to-Back) Double Head Post (Back-to-Back) Powerhead 14" x 38" 14" x 21" Powerhead 14" x 34-1/2" Powerhead 9" x 30" Key Unmetered Metered A 65" 77-1/2" B — 45-1/4" C 19-1/8" 19-1/8" D 9" 9" E 4-3/8" 4-3/8" F 18" 18" G 6" 6" Key 100A Metered 200A Metered A 83-1/2" 83-1/2" B 51-1/4" 48-3/4" C 47" 47" D 9" 9" E 4-3/8" 4-3/8" F 18" 18" G 6" 6" Key Unmetered Metered A 83-1/2" 86" B — 50" C 49-1/2" 49-1/2" D 9" 9" E 4-3/8" 4-3/8" F 18" 18" G 6" 6" Key Metered A 83-1/2" B 48-3/4" C 6" D 9-1/2" E 4-3/8" F 18" 14PT 9PT 14HP 9HP Post Dimensions Earth Burial Midwest Electric Products Service Equipment 25 Data subject to change without notice. Service Equipment Key Unmetered Metered A 83-1/2" 84" B — 51-1/2" C 46-1/2" 46-1/2" D 9-1/2" 9-1/2" E 3-1/2"1 4-1/2" F 18" 18" G 6" 6" X 21-1/2" 30" Y 9-1/2" 9-1/2" Key Metered A 83-1/2" B 49" C 46-1/2" D 9-1/2" E 4-1/2" F 18" G 6" X 35" Y 14" 6H 6H034 Post Dimensions Earth Burial 1 Some models available in 4-3/8". Contact the distributor/manufacturer. Midwest Electric Products Service Equipment 26 Data subject to change without notice. Service Equipment Wire Range Tables AB Connector Copper Aluminum Solid Strand Solid Strand Line — — — — Load 14-8 14-1/0 12-8 12-1/0 Neutral - Large Hole 12-8 2-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 AD Connector Copper Aluminum Solid Strand Solid Strand Line — 6-1/0 — 6-1/0 Load — — — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 AF Connector Copper Aluminum Solid Strand Solid Strand Line — 1/0-250 kcmil — 1/0-250 kcmil Load — 1-300 kcmil — 1-300 kcmil Neutral — 1/0-250 kcmil — 1/0-250 kcmil Equipment Ground 12-8 12-2 12-8 12-2 AN Connector Copper Aluminum Solid Strand Solid Strand Line Main Lugs — — — — Load CB Base — 1-300 kcmil — 1-300 kcmil Neutral - Large Single Lugs — 1-300 kcmil — 1-300 kcmil Neutral - Small Single Holes 14-8 14-1/0 12-8 12-1/0 Neutral - Six Large Holes 14-8 10-4 — 6-4 Neutral - Small Holes 14-8 12-8 12-8 12-8 Equipment Ground 12-8 12-2 12-8 12-2 AS Connector Copper Aluminum Solid Strand Solid Strand Line — 6-1/0 — 6-1/0 Load — — — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 Post Line Connectors Suitable for Loop Feed 2-350 kcmil 2-350 kcmil Equipment Ground 12-2 12-2 12-2 12-2 AT Connector Copper Aluminum Solid Strand Solid Strand Line — 6-1/0 — 6-1/0 Load — — — — Neutral 12-8 12-1/0 10-8 10-1/0 Neutral 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 Post Line Connectors Suitable for Loop Feed 6-350 kcmil 6-350 kcmil Equipment Ground 12-2 12-2 12-2 12-2 AW Connector Copper Aluminum Solid Strand Solid Strand Line — 1/0-4/0 — 1/0-4/0 Load — 1/0-4/0 — 1/0-4/0 Neutral — 2-4/0 — 2-4/0 Equipment Ground 12-8 12-2 12-8 12-2 AX Connector Copper Aluminum Solid Strand Solid Strand Line — 1/0-4/0 — 1/0-4/0 Load — 1/0-4/0 — 1/0-4/0 Neutral A — 2-4/0 — 2-4/0 Neutral B 12-8 12-1/0 10-8 10-1/0 Neutral C 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 BC Connector Copper Aluminum Solid Strand Solid Strand Line — 1/0-250 — 1/0-250 Load — 1/0-250 — 1/0-250 Neutral — 2-250 — 2-250 Neutral 12-8 12-1/0 10-8 10-1/0 Neutral 14-8 14-4 12-8 12-4 Equipment Ground — 2-250 — 2-250 Equipment Ground 14-8 14-1/0 12-8 12-1/0 BD Connector Copper Aluminum Solid Strand Solid Strand Line — 1/0-4/0 — 1/0-4/0 Load — 2-4/0 — 1/0-4/0 Neutral — 2-4/0 — 1/0-4/0 Equipment Ground 12-8 12-2 12-8 12-2 Midwest Electric Products Service Equipment 27 Data subject to change without notice. Service Equipment Wire Range Tables BF Connector Copper Aluminum Solid Strand Solid Strand Line — 1-4/0 — 2/0-4/0 Load — 1-4/0 — 2/0-4/0 Neutral — 1-4/0 — 1-4/0 Equipment Ground — 6-2/0 — 6-2/0 BG Connector Copper Aluminum Solid Strand Solid Strand Line — 1-4/0 — 2/0-4/0 Load — 1-4/0 — 2/0-4/0 Neutral A — 1-4/0 — 1-4/0 Neutral/Ground B — 6-2/0 — 6-2/0 Neutral/Ground C 14-8 14-4 12-8 12-4 BJ Connector Copper Solid Strand Line Meter Socket — 6-4/0 Load Base Lugs — 1-4/0 Neutral A — 1-4/0 Neutral/Ground B — 6-2/0 Neutral/Ground C 14-8 14-4 BK Connector Copper Aluminum Solid Strand Solid Strand Line Meter Socket — 6-350 mcm — 6-350 mcm Load Base Lugs — 1-4/0 — 1-4/0 Neutral A — 1-4/0 — 1-4/0 Neutral/Ground B — 6-2/0 — 6-2/0 Neutral/Ground C 14-8 14-4 12-8 12-4 BM Connector Copper Aluminum Solid Strand Solid Strand Line — 6-300 — 6-350 Load — 1-300 — 1-300 Neutral A — 1-300 — 1-300 Neutral B — 6-2/0 — 6-2/0 Neutral C 14-8 14-1/0 12-1/0 12-1/0 BZ Connector Copper Aluminum Solid Strand Solid Strand Load — 4/0-350 — 300-500 Neutral A — 2-600 — 2-600 Neutral B — 6-350 — 6-350 S Connector Copper Aluminum Solid Strand Solid Strand Post Line Connectors Suitable for Loop Feed 6-350 kcmil 6-350 kcmil Equipment Ground 12-2 12-2 T2 Connector Copper Aluminum Solid Strand Solid Strand Post Line Connectors Suitable for Loop Feed 2-250 kcmil 2-250 kcmil Equipment Ground 12-2 12-2 V Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Load — — — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 W Connector Copper Aluminum Solid Strand Solid Strand Equipment Ground (2) 14 (2) 14 — — Equipment Ground (2) 12 (2) 12 (2) 12 (2) 12 Equipment Ground (2) 10 (2) 10 (2) 10 (2) 10 Equipment Ground (1) 12, (1) 14 — — — Equipment Ground (1) 10, (1) 14 — — — Equipment Ground (1) 10, (1) 12 — (1) 10, (1) 12 — Equipment Ground (1) 8-4 (1) 8-4 — (1) 8-4 Z Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Load 14-8 14-1/0 12-8 12-1/0 Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 400 Amps Connector Copper Aluminum Solid Strand Solid Strand Line1 — — — — Load 1 1-300 — 1-300 — Neutral N1 — 1-300 — 1-300 Equipment Ground 6-2/0 6-2/0 6-2/0 6-2/0 1 Crimp-on/connector lug is not supplied by Midwest. Midwest Electric Products Service Equipment 28 Data subject to change without notice. Service Equipment Aluminum Mobile Home Specications ? NEMA 3R weatherproof construction ? 14-gauge aluminum power head construction ? Durable polyester powder coat finish resists chipping and fading (available in optional green finish) ? Suitable for use as service entrance equipment ? 22 kAIC amps RMS symmetrical short circuit rating ? Ring type, 4-jaw single phase meter socket series wired to main ? 600 MCM loop feed lugs on 3 and 4 socket models ? Available with up to 4 meters ? Available with 200 amp factory installed main breaker(s) ? Lockable, sealable covers with stainless steel latch ? Direct burial galvanized mounting posts supplied with adjustable foot extensions for increased stability Installation Features ? Multi-gang construction reduces the number of installations ? Modular construction allows post installation for trenching and feeder cables (power heads can be installed at a later time) ? Unique “cap-off” feature on post for splice through applications ? Light weight aluminum power head construction allows easy installation by a single electrician ? Rolled edges on all post wire entry points ? Removable access doors on both sides of power head MH1 and MH2 (Heads Only) MH3 and MH4 (Covers Removed) Midwest Electric Products Service Equipment 29 Data subject to change without notice. Service Equipment Basic Model Single and Multi-gang Power Heads, 200 Amps, 120/240V Fig. Model Number1, 2 Meter Sockets Power Heads Amps Main Breaker Hub Opening Unit Wt. UL A MH100S0 1 1 200 Not Included (125A Max Plug-in) N 22 Y B MH120B0 1 1 Included (200A Bolt-on) 22 A MH200S0 2 1 Not Included (125A Max Plug-in) 26 B MH220B0 2 1 Included (200A Bolt-on) 26 A MH300S0 3 2 Not Included (125A Max Plug-in) 39 B MH320B0 3 2 Included (200A Bolt-on) 39 B MH420B0 4 2 Included (200A Bolt-on) 52 1 All models available in optional green finish. Substitute trailing “0” with “1” (i.e., MH100S1). 2 Order post separately. Mounting Posts for Single and Multi-gang Power Heads Model Number1 Color Unit Wt.2 PEPOSTGRAY Gray 26 P2POST Green 1 Required for installation of power head. 2 Post is shipped separately. Dimensions 32” 9-1/2” 11” (1-2 Sockets) 15” (3-4 Sockets) 59” 6” 5” Grade Fig. A MH100SO, MH200SO, MH300SO Fig. B MH120BO, MH220BO, MH320BO, MH420BO Midwest Electric Products 30 AC Disconnects Midwest Electric Products AC Disconnects 31 Data subject to change without notice. AC Disconnects Application Information Article 440 of the National Electrical Code applies to electric motor-driven air conditioning and refrigerating equipment, and to the branch circuits and controllers for such equipment. It provides for the special considerations necessary for circuits supplying hermetic refrigerant motor-compressors and for any air conditioning and/or refrigerating equipment that is supplied from an individual branch circuit. The National Electric Code Requirements Disconnecting means shall be located within sight from and readily accessible from the air-conditioning or refrigerating equipment. The disconnecting means shall be permitted to be installed on or within the air-conditioning or refrigerating equipment. The disconnecting means shall not be located on panels that are designed to allow access to the air-conditioning or refrigeration equipment or to obscure the equipment nameplates. Additionally, the National Electric Code states that listed or labeled equipment shall be used or installed in accordance with any instructions included in the listing or labeling. Thus, when an equipment’s label or instruction specifies circuit breaker protection, Article 110.3(b) can be met with a branch circuit breaker in the load center while article 440.14 can most economically be met using a disconnect without overcurrent protection. When an equipment’s label or instructions specifies fuse protection, Article 110.3(b) mandates that fuse(s) must be present in the branch circuit. Since most load centers are of the circuit breaker variety, fuses must be installed elsewhere in the branch circuit. The most economical installation involves combining the fuse protection and disconnecting functions into a single device to be installed per Article 440.14. See illustrations. Features and Benets Flexibility ? 30-100 Amps ? 240 volts AC ? 1-phase or 3-phase fusible or non-fusible ? Horsepower rated ? 10kAIC ? Available with GFCI receptacle Rugged Durability ? NEMA 3R weatherproof enclosure ? Noryl? thermoplastic enclosure is corrosion resistant and extremely durable, giving long maintenance free service ? Metallic models are made of G90 galvanized steel for superior corrosion protection and have a durable polyester powder coat finish which resists chipping and fading User Safety ? Padlock provision on door helps prevent unauthorized access Installation Ease ? Three-piece construction that opens up mounting and wiring areas ? Terminals approved for 60°C and 75°C wire, accepts solid 14-8 copper, 12-8 aluminum or stranded 14-3 copper, 12-3 aluminum ? Numerous knockouts reduce installation time ? Straight-in, straight-out wiring saves time and money Air Conditioner Disconnect Selection Guide Existing Branch Circuit Protection Sight Disconnect Selection Fusible1 Non-Fusible or Fusible Circuit Breaker Fusible HACR2 Non-Fusible or Fusible 1 See Air Conditioner nameplate for correct selection. 2 HACR = Heating, air conditioning, refrigeration type circuit breaker. U065P010 Midwest Electric Products AC Disconnects 32 Data subject to change without notice. AC Disconnects Non-Metallic Fusible / Non-Fusible, 30 – 60 Amps, 120/240V Metallic 1-phase / 3-phase, Fusible / Non-Fusible, 30 – 60 Amps, 120/240V or 240V Fig. A P035F, P065F Fusible Fig. D U035F2, U065F1 Fusible Fig. C P065P1, P065P Non-Fusible Fig. F U0353F, U0653F Fusible Fig. B P065NA1 Non-Fusible Fig. E U065P Non-Fusible Fig. G U0653P Non-Fusible Fig. Model Number Amps Horsepower Rating Wire Range* Cabinet Size Unit Wt. Std Pkg. UL Fusible Non-Fusible A P035F — 30 3 D 6 x 8 2 6 Y1 A P065F — 60 10 6 x 8 B — P065NA1 60 10 5 x 7 C — P065P1 60 10 5 x 7 C — P065P 60 10 6 x 8 1 cULus approved. * Wire Range Table on page 36. See technical data on page 35 for available replacement parts. Fig. Model Number Amps Horsepower Rating Wire Range* Cabinet Size Unit Wt. Std Pkg. UL Fusible Non-Fusible Phase 1 – 120/240V D U035F2 — 30 3 D 5 x 7 2.5 D U065F1 — 60 10 5 x 9 3.5 6 Y1 E — U065P 60 10 5 x 7 3 Phase 3 – 240V E U0353F — 30 3-7.5 F U0653F — 60 7.5-15 D 6 x 14 8.5 4 Y1 G — U0653P 60 7.5-15 1 cULus approved. * Wire Range Table on page 36. See technical data on page 35 for available replacement parts. Fusible disconnects are available in 30 and 60 Amp models. Pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. The P065F UL listing includes the ability to field replace the 60 Amp puller with a 30 Amp puller (FR352) for installation flexibility. Listed for use as service entrance. Non-fusible disconnect pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. Fusible disconnects are available in 30 and 60 Amp models. Pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. Listed for use as service entrance. Non-fusible disconnect pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. Key = Accepts Class H fuses (fuses not included) Midwest Electric Products AC Disconnects 33 Data subject to change without notice. AC Disconnects Non-Automatic 1-phase, 60 Amps, 120/240V Model Number Phase Amps Horsepower Rating Wire Range* Cabinet Size Unit Wt. Std Pkg. UL U065NA1 1 60 10 D 5 x 7 2.5 6 Y1 1 cULus approved. * Wire Range Table on page 36. Heat Pump Fusible, 90 – 100 Amps, 120/240V Fig. A U045F Fig. B U610F Fig. Model Number Amps Horsepower Rating Neutral Bar Wire Range* Cabinet Size Unit Wt. Std Pkg. UL Fusible A U045F 90 10 NU100B2 Y 9 x 17 13.5 1 Y B U610F 100 * Wire Range Table on page 36. See technical data on page 35 for available replacement parts. Line Load 30A 60A Line Load 60A 60A Multiple disconnect devices are offered for heat pump applications that require individual disconnects for the heating and cooling cycles. All pullers are removable or reinstallable in the OFF position for user safety during equipment maintenance. Their UL listing includes the ability to field replace the 60 Amp puller in the left fuse block with a 30 Amp puller (FR352) for installation flexibility but prohibits the interchangeability of pullers between fuse blocks to insure the proper fuse/puller combination is always reinstalled into the proper fuse block. AC with Ground Fault 1-phase, 60 Amps, 120/240V Model Number Phase Receptacle Amps Horsepower Rating Wire Range* Cabinet Size Unit Wt. Std Pkg. UL U065P010 1 5-15R2GFI 60 10 D 5 x 7 4.3 6 U065NA1010 1 5-15R2GFI 4 6 Y1 U065PC2 1 5-20R2 4.3 4 1 cULus approved. * Wire Range Table on page 36. See technical data on page 35 for available replacement parts. Midwest Electric Products AC Disconnects 34 Data subject to change without notice. AC Disconnects Evaporative Cooler Fusible, 20 – 40 Amps, 120/240V Fig. A U220H Fig. B U261F Fig. C STC1 Fig. Model Number Receptacle Circuit Protection Amps Wire Range* Cabinet Size Unit Wt. Std Pkg. UL Fusible A U220H DPST, SPST Switch (2) FH1 20 AR 5 x 7 4.5 4 N B U261F 14-20R, 5-20R2 (3) FH1 40 E 6 x 9 6 Y1 1 cULus approved. * Wire Range Table on page 36. 14-20R 5-20R2 Evaporative cooler applications not only require fusing but switching or receptacle functions depending on equipment type and local codes. Two models are offered to meet these varied evaporative cooler applications. Mounting Bracket Exterior Fig. Model Number Orientation Description Std Pkg. C STC1 Exterior For AC and AC/GFI in aluminum, vinyl siding and stucco applications 6 Key = Accepts Class H fuses (fuses not included) = Edison plug fuse base (fuses not included) Midwest Electric Products AC Disconnects 35 Data subject to change without notice. AC Disconnects Technical Data Cabinet Dimensions Model Number Replacement Parts Cabinet Size Enclosure Style Cabinet Dimensions (inches) Knockout Complete Block Figure1 and Puller Fuse Block Only Puller Only Height (A) Width (B) Depth (C) Depth (D) P035F FR39 — FR352 6 x 8 C 8 5-3/4 3-1/8 — 1 P065F FR69 — FH682 6 x 8 C 8 5-3/4 3-1/8 — 1 P065NA1 — — — 5 x 7 D 7-1/4 5 2-1/8 2-3/4 2 P065P — NF65 NF652 6 x 8 D 8 6 5-3/4 2-3/4 2 P065P1 — NF65 NF652 5 x 7 D 7 5 2-1/8 2-3/4 2 U035F2 FR35R — FR352R 5 x 7 A 7 5 2-1/8 2-3/4 2 U0353F 265A6035G27 — 265A6035G27 6 x 14 B 14-3/8 7-1/4 5-3/16 — 3 U045F FR35XFR67 — FR352, FH682 9 x 17 B 17-3/8 9-3/4 5-3/16 — 4 U0653F 265A6036G69 — 265A6036G69 6 x 14 B 14-3/8 7-1/4 5-3/16 — 3 U0653P 265A6036G73 — 265A6036G73 6 x 14 B 14-3/8 7-1/4 5-3/16 — 3 U065F1 FR65 — FH682 5 x 9 A 9 5 2-1/8 2-3/4 2 U065NA1 — — — 5 x 7 D 7 5 2-1/8 2-3/4 2 U065NA1010 — — — 5 x 7 D 7 5 3-5/8 5-3/16 2 U065P — NF65 NF652 5 x 7 A 7-1/4 5 2-1/8 2-3/4 2 U065P010 — NF65 NF652 5 x 7 D 7 5 3-5/8 5-3/16 2 U065PC2 — NF65 NF652 5 x 7 D 7 5 2-1/8 2-3/4 2 U220H — FH1 — 5 x 7 B 7-1/8 5-3/4 5-3/16 — 5 U261F — FH1 — 6 x 9 B 9-1/8 7-1/4 5-3/16 — 3 U610F FR67X2 — FH682 9 x 17 B 17-3/8 9-3/4 5-3/16 — 4 1 Knockout Figures on page 36. Fig. A Fig. B Fig. C Fig. D A B C D B C A B C A A B C D Midwest Electric Products AC Disconnects 36 Data subject to change without notice. AC Disconnects Knockout Congurations Wire Range Tables Fig. 1 Fig. 4 Fig. 2 Fig. 3 Fig. 5 W W L W Y L G G B G G B G D G L M L G G G G G G G G G G G G * Knockouts shown for size not for exact positions. Knockout Key B = 1", 1-1/4", 1-1/2" D = 3/4", 1", 1-1/4" G = 1/2", 3/4", 1" L = 1/2", 3/4" M = 1/2", 3/4", 1", 1-1/4" W = 3/4", 1" Y = 1", 1-1/4" D Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-2 12-8 12-2 Load 14-8 14-2 12-8 12-2 Neutral — — — — Equipment Ground 12-8 12-2 12-8 12-2 E Connector Copper Aluminum Solid Strand Solid Strand Line 14-10 14-10 — — Load 14-10 14-10 — — Neutral 14-10 14-10 — — Equipment Ground 12-8 12-2 — — Y Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Load 14-8 14-2 12-1/0 12-2 Neutral 14-8 14-1/0 12-8 12-1/0 AR Connector Copper Aluminum Solid Strand Solid Strand Line 14-10 14-10 — — Load 14-10 14-10 — — Neutral — — — — Equipment Ground 12-8 12-2 — — Midwest Electric Products AC Disconnects 37 Data subject to change without notice. AC Disconnects Notes Data subject to change without notice. Midwest Electric Products 38 Temporary Power Midwest Electric Products Temporary Power 39 Data subject to change without notice. Temporary Power Application Information Prior to permanently installing service equipment on a new structure, temporary power is typically installed to support the various construction trades. Electricians that are not familiar with Midwest Electric’s Site-Power? line usually construct their own temporary power arrangement using a combination of individual outdoor rated components (meter box, load center and multiple receptacles) assembled on a sheet of plywood and anchored to the ground with dimension lumber. While sufficient to do the job, this arrangement is labor intensive, has multiple conduit connections with the potential for water intrusion and is not well protected against unauthorized use. Site-Power? temporary power equipment from Midwest Electric combines the metering, circuit protection and power outlet combinations that are required on most construction sites. Every unit is delivered to the job site ready to go with factory installed and wired components — giving you the assurance needed for a reliable and safe temporary power unit. All Site-Power? enclosures are constructed from heavy-gauge G90 galvanized steel for superior corrosion resistance. The durable polyester powder coat finish resists chipping and fading. The equipment door is designed to protect power cords and plugs and has a padlock provision to guard against unauthorized use or vandalism. Features and Benets Rugged Durability ? Rolled edge door for cord protection ? Continuous duty meter socket with meter guides and reinforced jaws – ringless and ring type ? Utility accepted meter sealing accommodations ? NEMA 3R weatherproof construction ? G90 galvanized steel construction for superior corrosion resistance ? Durable polyester powder coat finish resists chipping and fading ? 10kAIC ? All GFCI duplexes are listed as weather resistant and tamper resistant as required by NEC in Article 406.8 and 406.11 Installation Ease ? All components factory wired and assembled, reducing installation time ? Door removable for installation ease; stay open position for user convenience ? All terminals accept copper or aluminum wire for added installation flexibility ? Wide range of receptacle configurations ? Broad range of concentric knockouts to accommodate varied wiring needs ? All units with factory installed Cu/Al equipment ground lug User Safety ? Dead front construction prevents accidental contact with live parts ? Padlock provision to prevent unauthorized access All-In-One Design ? Includes circuit breakers, receptacles and meter socket (if required) ? Available with GFI circuit breakers ? Eliminates construction delays due to red tag code violations ? All ringless meter socket models have standard horn bypass ? Conforms to NEC and NEMA standards U055C010 Midwest Electric Products Temporary Power 40 Data subject to change without notice. Temporary Power Unmetered 30 – 40 Amps, 120/240V Fig. A U030 14-30R Fig. B U036C010 6-20R, 5-20R2GFCI Fig. C U036C033 6-20R, 5-20R2GFCI Fig. D U036G 6-20R, 5-20R2 20 20 GFI 20 20 GFI GFI 20 20 GFI Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U030 14-30R — 30 G 5 x 7 Y — 4.5 1 Y B U036C010 6-20R, 5-20R2GFCI CB220, CB120 40 K 6 x 14 LC33N7 10 4 C U036C033 6-20R, Y1 5-20R2GFCI GFI230, CB120 40 K 6 x 14 LC33N7 10 4 D U036G 6-20R, 5-20R2 CB220, GFI230 40 K 6 x 14 LC33N7 10 4 1 cULus approved. * Wire Range Table on page 49. Midwest Electric Products Temporary Power 41 Data subject to change without notice. Temporary Power Unmetered 70 Amps, 120/240V Fig. C U051C 10-50R, 5-20R2 Fig. H U055C010 BR54U, 5-20R2GFCI Fig. I U055C033 BR54U, 5-20R2GFCI Fig. J U055G BR54U, 5-20R2 Fig. D U051C010 10-50R, 5-20R2GFCI Fig. E U051C033 10-50R, 5-20R2GFCI Fig. F U051G 10-50R, 5-20R2 Fig. A U011C010 (2) 5-20R2GFCI Fig. G U054C BR54U Fig. B U011G (2) 5-20R2 50 20 50 20 GFI 50 20 GFI 50 GFI 20 GFI 50 GFI 20 GFI 50 20 GFI 50 20 GFI GFI GFI SPACE 20 20 50 SPACE SPACE 20 GFI 20 GFI Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U011C010 (2) 5-20R2GFCI (2) CB120, Space CB120 70 K 6 x 14 Y LC33N7 10 4 Y1 B U011G (2) 5-20R2 (2) GFI120, Space CB120 70 K C U051C 10-50R, 5-20R2 CB250, CB120 70 K N D U051C010 10-50R, 5-20R2GFCI CB250, CB120 70 K E U051C033 10-50R, 5-20R2GFCI GFI250, CB120 70 K F U051G 10-50R, 5-20R2 CB250, GFI120 70 K G U054C BR54U CB250, Space CB120 70 O Y1 H U055C010 BR54U, 5-20R2GFCI CB250, CB120 70 K I U055C033 BR54U, 5-20R2GFCI GFI250, CB120 70 K J U055G BR54U, 5-20R2 CB250, GFI120 70 K 1 cULus approved. * Wire Range Table on page 49. Midwest Electric Products Temporary Power 42 Data subject to change without notice. Temporary Power Unmetered 90 – 125 Amps, 120/240V Fig. G U072C (2) BR54U Fig. C U038C010 6-20R, (2) 5-20R2GFCI Fig. A U073G BR54U, 6-20R, 5-20R2 Fig. B U011GTL (2) 5-20R2 Fig. H U076C010 BR54U, (2) 5-20R2GFCI Fig. D U038C033 6-20R, (2) 5-20R2GFCI Fig. I U076C033 BR54U, (2) 5-20R2GFCI Fig. E U038CTL010 6-20R, (2) 5-20R2GFCI Fig. J U076G BR54U, (2) 5-20R2 Fig. F U038G 6-20R, (2) 5-20R2 Fig. K U039G6 L6-30R, (2) L5-20R 20 GFI 50 20 SPACE 20 GFI 20 GFI SPACE 50 50 20 20 GFI GFI SPACE 20 50 GFI 20 GFI GFI 20 20 20 GFI GFI SPACE 20 SPACE 20 GFI 20 GFI 50 SPACE 20 GFI 20 GFI 20 30 GFI 20 GFI SPACE 20 GFI 50 20 GFI GFI SPACE 20 20 GFI 20 GFI GFI SPACE 20 Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U073G BR54U, 6-20R, 5-20R2 CB250, CB220, GFI120 90 U 9 x 17 Y LC55N1 16 1 Y2 B U011GTL (2) 5-20R2 (2) GFI120, Space CB120 100 U 9 x 17 LC33N1T 14.5 4 C U038C010 6-20R, (2) 5-20R2GFCI CB220, (2) CB120 100 AA 9 x 17 LC55N1 15 1 D U038C033 6-20R, (2) 5-20R2GFCI GFI220, (2) CB120, Space CB120 100 AA 9 x 17 LC55N1 15 1 E U038CTL0101 6-20R, (2) 5-20R2GFCI CB220, (2) CB120, Space CB120 100 AA 9 x 17 LC55N1T 16 1 F U038G 6-20R, (2) 5-20R2 CB220, (2) GFI220, Space CB120 100 U 9 x 17 LC55N1 15 1 G U072C (2) BR54U (2) CB250, Space CB120 100 V 9 x 17 LC55N1 16 1 H U076C010 BR54U, (2) 5-20R2GFCI CB250, (2) CB120, Space CB120 100 AA 9 x 17 LC55N1 16 1 I U076C033 BR54U, (2) 5-20R2GFCI (2) CB120, GFI250 100 AA 9 x 17 LC55N1 16 1 J U076G BR54U, (2) 5-20R2 CB250, (2) GFI120, Space CB120 100 U 9 x 17 LC55N1 16 1 K U039G6 L6-30R, (2) L5-20R GFI230, (2) GFI120, Space CB120 125 C 9 x 21 LC88PC 16 1 1 Available with GFI dual-pole breaker in place of GFI receptacle – replace “010” with “033”. 2 cULus approved. * Wire Range Table on page 49. Midwest Electric Products Temporary Power 43 Data subject to change without notice. Temporary Power Metered Top Feed, 40 – 90 Amps, 120/240V Fig. A M036C010, R036C010 6-20R, 5-20R2GFCI Fig. G M055C033, R055C033 BR54U, 5-20R2GFCI Fig. H M055G, R055G BR54U, (2) 5-20R2 Fig. I M055GP6033 BR54U, 5-20R2 Fig. J M076C010, R076C010 BR54U, (2) 5-20R2GFCI Fig. K M076C033, R076C033 BR54U, (2) 5-20R2GFCI Fig. B M036C033 6-20R, 5-20R2GFCI Fig. C M036G, R036G 6-20R, 5-20R2 Fig. D M051C010 10-50R, 5-20R2GFCI Fig. E M051G 10-50R, 5-20R2 Fig. F M055C010, R055C010 BR54U, 5-20R2GFCI 20 20 GFI 50 GFI 20 GFI 20 20 GFI GFI 50 20 GFI 20 20 GFI 50 GFI 20 GFI POST 50 20 GFI 50 20 GFI 50 GFI 20 20 GFI GFI 50 20 GFI GFI SPACE 20 50 20 GFI Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL Ringtype Ringless A M036C010 R036C010 6-20R, 5-20R2GFCI CB220, CB120 40 AA 9 x 30 Y LC33N1 25 1 B M036C033 — 6-20R, Y2 5-20R2GFCI GFI230, CB120 40 AA 9 x 30 LC33N1 23 C M036G R036G 6-20R, 5-20R2 CB220, GF1120 40 AA 9 x 30 LC33N1 25 D M051C010 — 10-50R, 5-20R2GFCI CB250, CB120 70 AA 9 x 30 LC33N1 25 N E M051G — 10-50R, 5-20R2 CB250, GF1120 70 AA 9 x 30 LC33N1 25 F M055C010 R055C010 BR54U, 5-20R2GFCI CB250, CB120 70 K 9 x 30 LC33N1 25 Y2 G M055C033 R055C033 BR54U, 5-20R2GFCI GFI250, CB120 70 K 9 x 30 LC33N1 23 H M055G R055G BR54U, 5-20R2 CB250, GFI120 70 AA 9 x 30 LC33N1 25 I M055GP60331 — BR54U, 5-20R2 GFI120, GFI250 70 A2 9 PT LC33N1 51 J M076C010 R076C010 BR54U, (2) 5-20RGFCI CB250, (2) CB120, Space CB120 90 AA 9 x 30 LC55N1 25 K M076C033 R076C033 BR54U, (2) 5-20RGFCI GFI250, (2) CB120, Space CB120 90 AA 9 x 30 LC55N1 25 1 Earth Burial Post. See page 90 for post mounted dimensions. 2 cULus approved. * Wire Range Table on page 49. Midwest Electric Products Temporary Power 44 Data subject to change without notice. Temporary Power Metered Top Feed, 100 Amps, 120/240V Fig. B M011G, R011G (2) 5-20R2 Fig. A M011C010, R011C010 (2) 5-20R2GFCI Fig. C M038C010, R038C010 6-20R, (2) 5-20R2GFCI Fig. E M038CB1010 6-20R, (2) 5-20R2GFCI Fig. D M038C033, R038C033 6-20R, (2) 5-20R2GFCI Fig. F M038CB1033 6-20R, (2) 5-20R2GFCI Fig. G R038CP4010 6-20R, (2) 5-20R2GFCI GFI GFI SPACE 20 20 SPACE 20 GFI 20 GFI 20 GFI 20 GFI GFI SPACE 20 20 GFI 20 GFI GFI SPACE 20 BARRIER 20 20 GFI GFI SPACE 20 20 20 GFI GFI SPACE 20 BARRIER 20 20 GFI GFI SPACE 20 POST Fig. H R038CP4033 6-20R, (2) 5-20R2GFCI 20 GFI 20 GFI GFI SPACE 20 POST Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL Ringtype Ringless A M011C010 R011C010 (2) 5-20R2GFCI (2) CB120, Space CB120 100 AA 9 x 30 Y LC33N1 21 1 Y2 B M011G R011G (2) 5-20R2 (2) GFI120, Space CB120 100 AA 9 x 30 LC33N1 21 1 C M038C010 R038C010 6-20R, (2) 5-20R2GFCI CB220, (2) CB120, Space CB120 100 AA 9 x 30 LC55N1 25 1 D M038C033 R038C033 6-20R, (2) 5-20R2GFCI GFI220, (2) CB120, Space CB120 100 AA 9 x 30 LC55N1 24 1 E M038CB1010 — 6-20R, (2) 5-20R2GFCI CB220, (2) CB120, Space CB120 100 AA 14 x 26 LC55N1 33 1 Y F M038CB1033 — 6-20R, (2) 5-20R2GFCI GFI220, (2) CB120, Space CB120 100 AA 14 x 26 LC55N1 33 1 G — R038CP40101 6-20R, (2) 5-20R2GFCI CB220, (2) CB120, Space CB120 100 A2 9 PT LC55N1 45 1 H — R038CP40331 Y2 6-20R, (2) 5-20R2GFCI GFI220, (2) CB120, Space CB120 100 A2 9 PT LC55N1 45 1 I M038G R038G 6-20R, (2) 5-20R CB220, (2) GFI120, Space CB120 100 AA 9 x 30 LC55N1 25 4 J M038GB1 — 6-20R, (2) 5-20R CB220, (2) GFI120, Space CB120 100 AA 14 x 26 LC55N1 35 1 Y K M038GB1033 — 6-20R, (2) 5-20R2 GFI220, (2) GFI120, Space CB120 100 AA 14 x 26 LC55N1 35 1 1 Pad Mount Post. See page 90 for post mounted dimensions. 2 cULus approved. * Wire Range Table on page 49. Fig. J M038GB1 6-20R, (2)5-20R Fig. K M038GB1033 6-20R, (2)5-20R 20 20 GFI SPACE 20 GFI BARRIER 20 GFI 20 GFI SPACE 20 GFI BARRIER Fig. I M038G, R038G 6-20R, (2)5-20R SPACE 20 GFI 20 GFI 20 Midwest Electric Products Temporary Power 45 Data subject to change without notice. Temporary Power Metered Bottom Feed, 40 – 100 Amps, 120/240V Fig. A M036C010U 6-20R, 5-20R2GFCI Fig. G M038C010U, R038C010U 6-20R, (2) 5-20R2GFCI Fig. B M055C010U, R055C010U BR54U, 5-20R2GFCI Fig. H M038C033U, R038C033U 6-20R, (2) 5-20R2GFCI Fig. C M055C033U, R055C033U BR54U, 5-20R2GFCI Fig. I R038GU 6-20R, (2) 5-20R2 Fig. D M076C010U, R076C010U BR54U, (2) 5-20R2GFCI Fig. J M041C010U R32U, 5-20R2GFCI Fig. E M011C010U, R011C010U (2) 5-20R2GFCI Fig. K M075C010U, R075C010U BR54U, R32U, 5-20R2GFCI Fig. F R031C010U R32U, (2) 5-20R2GFCI Fig. L M355C010U BR54U, 5-20R2GFCI 20 20 GFI 20 20 GFI GFI SPACE 20 50 20 GFI 20 GFI 20 GFI GFI SPACE 20 50 20 GFI GFI 20 20 GFI 20 GFI SPACE 30 20 GFI SPACE 50 30 20 GFI SPACE 50 20 GFI SPACE SPACE 50 20 GFI GFI SPACE 20 GFI GFI SPACE 20 20 30 20 20 GFI GFI SPACE SPACE Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL Ringtype Ringless A M036C010U — 6-20R, 5-20R2GFCI CB220, CB120 40 X 9 x 30U N LC33N1 25 1 Y1 B M055C010U R055C010U BR54U, 5-20R2GFCI CB250, CB120 70 H 9 x 30U N LC33N1 25 C M055C033U R055C033U BR54U, 5-20R2GFCI GFI250, CB120 70 H 9 x 30U Y LC33N1 23 D M076C010U R076C010U BR54U, (2) 5-20R2GFCI CB250, (2) CB120, Space CB120 90 X 9 x 30U N LC55N1 25 E M011C010U R011C010U (2) 5-20R2GFCI (2) CB120, Space CB120 100 X 9 x 30U N LC33N1 21 F — R031C010U R32U, (2) 5-20R2GFCI CB130, (2) CB120 100 AA 9 x 30U Y LC55N1 25 G M038C010U R038C010U 6-20R, (2) 5-20R2GFCI CB220, (2) CB120, Space CB120 100 X 9 x 30U N LC55N1 25 H M038C033U R038C033U 6-20R, (2) 5-20R2GFCI GF1220, (2) CB120, Space CB120 100 X 9 x 30U Y LC55N1 26 I — R038GU 6-20R, (2) 5-20R2 CB220, (2) GFI120 100 X 9 x 30U N LC55N1 25 J M041C010U — R32U, 5-20R2GFCI CB130, CB120, Space CB120 100 AA 9 x 30U Y LC33N1 25 K M075C010U R075C010U BR54U, R32U, 5-20R2GFCI CB250, CB130, CB120, (1) Space 100 AA 9 x 30U Y LC55N1 25 L M355C010U — BR54U, 5-20R2GFCI CB250, CB120, (2) Space CB120 100 AA 9 x 30U Y LC55N1 25 1 cULus approved. * Wire Range Table on page 49. Midwest Electric Products Temporary Power 46 Data subject to change without notice. Temporary Power Technical Data Model Number Replacement Parts Cabinet Size Enclosure Style1 Cabinet Dimensions (inches) Knockout Meter Socket Height (A) Width (B) Depth (C) Figure2 M011C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M011C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 M011G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M036C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M036C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 M036C033 MSM100930 9 X 30 B 30 9-3/4 5-3/16 2 M036G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M038C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M038C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 M038C033 MSM100930 9 X 30 B 30 9-3/4 5-3/16 2 M038C033U MSM100EZ 9 X 30U C 30 9-3/4 5-3/16 3 M038CB1010 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4 M038CB1033 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4 M038G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M038GB1 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4 M038GB1033 MSM10014 14 x 26 B 26-1/4 14-3/4 4-9/16 4 M041C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4 M051C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M051G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M055C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M055C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 M055C033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M055C033U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 M055G MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M055GP6033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M075C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4 M076C010 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M076C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 M076C033 MSM100930 9 x 30 B 30 9-3/4 5-3/16 2 M355C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4 R011C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R011C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R011G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R031C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4 R036C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R036C010U MSR100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R036G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R038C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R038C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R038C033 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R038C033U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R038CP4010 MSR100EZ 9 PT B 30 9-3/4 5-3/16 2 R038CP4033 MSR100EZ 9 PT B 30 9-3/4 5-3/16 2 R038G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R038GU MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R055C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R055C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R055C033 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R055C033U MSM100EZ 9 X 30U C 30 9-3/4 5-3/16 3 R055G MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R075C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 4 R076C010 MSR100930 9 x 30 B 30 9-3/4 5-3/16 2 R076C010U MSM100EZ 9 x 30U C 30 9-3/4 5-3/16 3 R076C033 MSR100930 9 X 30 B 30 9-3/4 5-3/16 2 1 Enclosure Styles on page 47. 2 Knockout Figures on page 48. Midwest Electric Products Temporary Power 47 Data subject to change without notice. Temporary Power Technical Data Model Number Replacement Parts Cabinet Size Enclosure Style1 Cabinet Dimensions (inches) Knockout Meter Socket Height (A) Width (B) Depth (C) Figure2 U011C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U011G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U011GTL — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U030 — 5 x 7 A 7-1/8 5-3/4 5-3/16 1 U036C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U036C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U036G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U038C010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U038C033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U038CTL010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U038CTL033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U038G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U039G6 — 9 x 21 D 21 9-3/4 5-3/16 5 U051C — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U051C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U051C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U051G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U054C — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U055C010 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U055C033 — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U055G — 6 x 14 A 14-3/8 6-3/4 5-3/16 1 U072C — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U073G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U076C010 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U076C033 — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 U076G — 9 x 17 A 17-3/8 9-3/4 5-3/16 2 1 Enclosure Styles on page 47. 2 Knockout Figures on page 48. Cabinet Dimensions Fig. A Fig. D Fig. B Fig. C B C A B C A B C A A B C Midwest Electric Products Temporary Power 48 Data subject to change without notice. Temporary Power Knockout Congurations Fig. 1 Fig. 4 Fig. 2 Fig. 3 Fig. 5 G G G G G N G P P P W W A G G G N N G G G G W B G G G G D B B G * Knockouts shown for size not for exact positions. Knockout Key A = 1/2" B = 1", 1-1/4", 1-1/2" D = 3/4", 1", 1-1/4" G = 1/2", 3/4", 1" N = 1/2", 3/4", 1", 1-1/4", 1-1/2" P = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2" W = 1/2", 3/4", 1", 1-1/4", 2" Midwest Electric Products Temporary Power 49 Data subject to change without notice. Temporary Power Wire Range Tables AA Connector Copper Aluminum Solid Strand Solid Strand Line — 6-1/0 — 6-1/0 Load 14-10 14-10 — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 A2 Connector Copper Aluminum Solid Strand Solid Strand Line — 6-1/0 — 6-1/0 Load 14-10 14-10 — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 Post Line Connectors Suitable for Loop Feed 2-250 kcmil 2-250 kcmil Equipment Ground 12-2 12-2 12-2 12-2 C Connector Copper Aluminum Solid Strand Solid Strand Line — 1-300 — 1-300 Ground - Large Hole 12-8 12-1/0 12-10 10-1/0 Ground - Small Hole 14-8 14-4 12-10 10-1/0 Neutral - Large Hole 14-1/0 14-1/0 14-1/0 14-1/0 Neutral - Small Hole 14-6 14-6 14-6 14-6 G Connector Copper Solid Strand Line 12-8 12-4 Load — — Neutral 12-8 12-4 Equipment Ground 12-8 12-2 H Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-2 12-8 12-2 Load 14-10 14-10 — — Neutral — 6-350 — 6-350 Neutral — 1-300 — 1-300 Equipment Ground 12-8 12-2 12-8 12-2 K Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-2 12-8 12-2 Load 14-10 14-10 — — Neutral - End Hole 14-8 14-2 12-8 12-2 Neutral - Side Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 O Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-2 12-8 12-2 Load — — — — Neutral - End Hole 14-8 14-2 12-8 12-2 Neutral - Side Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 U Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Load 14-10 14-10 — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 V Connector Copper Aluminum Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Load — — — — Neutral - Large Hole 12-8 12-1/0 10-8 10-1/0 Neutral - Small Hole 14-8 14-4 12-8 12-4 Equipment Ground 12-8 12-2 12-8 12-2 X Connector Copper Aluminum Solid Strand Solid Strand Line — 6-1/0 — 6-1/0 Load 14-10 14-10 — — Neutral — 6-350 — 6-350 Neutral — 1-300 — 1-300 Equipment Ground 12-8 12-2 12-8 12-2 Data subject to change without notice. Midwest Electric Products 50 Power Outlets Midwest Electric Products Power Outlets 51 Data subject to change without notice. Power Outlets Application Information Portable equipment requiring electricity continues to increase steadily in both number and variety. This creates the need for conveniently located receptacles to provide power for cord connected equipment. Midwest Electric Power Outlets provide one or more receptacles, with or without overcurrent protection, in a single enclosure, eliminating the need for several separately mounted components while providing maximum protection against weather and normal field use. Additionally, many models also include disconnecting, metering, and/or pedestal mounting functions in a single NEMA 3R enclosure/assembly. Features and Benets ? NEMA 3R weatherproof construction ? G90 galvanized steel construction for superior corrosion resistance ? Durable polyester powder coat finish resists chipping and fading ? All in one construction for factory assured terminations ? Rolled edge door for cord protection ? Cover design allows cords to exist while maintaining the NEMA 3R integrity ? Wide assortments of concentric knockouts offer flexibility in the installation ? All GFCI duplexes are listed as weather resistant and tamper resistant as required by NEC in Article 406.8 and 406.11 ? Padlockable door to help prevent unauthorized access ? Dead front construction prevents accidental contact with live parts ? All components factory wired and assembled U013 U014C010 Midwest Electric Products Power Outlets 52 Data subject to change without notice. Power Outlets Unmetered Surface, 20 – 30 Amps, 120V Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U010 5-20R2 — 20 E 5 x 7 Y — 4.5 4 Y1 B U010F 5-20R2 FH2 20 E 5 x 7 — 4.5 C U010H 5-20R2 FH2, SP Switch 20 E 5 x 7 — 5 D U010010 5-20R2GFCI — 20 E 5 x 7 — 4.5 E U011 (2) 5-20R2 — 20 E 5 x 7 — 4.5 F U011010 (2) 5-20R2GFCI — 20 E 5 x 7 — 4.5 F U012010 (2) 5-20R2GFCI — 20 E 5 x 7 N — 4.5 G U013 R32U — 30 F 5 x 7 Y — 4.5 H U013C R32U CB130 30 A 6 x 9 LC31N3 7 I U013F R32U FH3 30 F 5 x 7 — 4.5 1 cULus approved. * Wire Range Table on page 62-63. Fig. A U010 5-20R2 Fig. F U011010, U012010 (2) 5-20R2GFCI Fig. B U010F 5-20R2 Fig. D U010010 5-20R2GFCI Fig. H U013C R32U Fig. C U010H 5-20R2 Fig. G U013 R32U Fig. E U011 (2) 5-20R2 Fig. I U013F R32U GFI GFI GFI 30 Midwest Electric Products Power Outlets 53 Data subject to change without notice. Power Outlets Unmetered Surface, 20 – 50 Amps, 120/240V Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U010C 5-20R2 CB120 20 B 6 x 9 Y LC31N3 7 4 Y2 B U011F (2) 5-20R2 (2) FH2 20 E 6 x 9 — 9 C U023 7310 — 20 F 5 x 7 — 4.5 N D U041 R32U, 5-20R2 — 30 E 6 x 9 — 6 E U041F R32U, Y2 5-20R2 FH3, FH2 30 E 6 x 9 — 7 F U041010 R32U, 5-20R2GFCI — 30 J 6 x 9 — 9 G U050 10-50R — 50 G 5 x 7 — 4.5 N H U051F 10-50R, 5-20R2 FH2 50 K 6 x 14 FR66 10 I U054 BR54U — 50 G 5 x 7 — 5 Y2 J U054F BR54U — 50 O 6 x 14 FR67 10 K U055010 BR54U, 5-20R2GFCI — 50 J 6 x 9 — 9 L U055F BR54U, 5-20R2 — 50 L 6 x 14 FR66, FH2 9 M U061C1 (2) R32U (2) CB130, Space CB120 50 O 6 x 14 LC33N7 10 N U550F BR54U, 5-20R2 FH2 50 M 6 x 14 — 6 1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC. 2 cULus approved. * Wire Range Table on page 62-63. Surface, 50 Amps, 240V Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL O U501 6-50R — 50 P 5 x 7 Y — 5 4 Y * Wire Range Table on page 63. Fig. A U010C 5-20R2 Fig. I U054 BR54U Fig. B U011F (2) 5-20R2 Fig. J U054F BR54U Fig. D U041 R32U, 5-20R2 Fig. F U041010 R32U, 5-20R2GFCI Fig. L U055F BR54U, 5-20R2 Fig. N U550F BR54U, 5-20R2 Fig. C U023 7310 Fig. K U055010 BR54U, 5-20R2GFCI Fig. E U041F R32U, 5-20R2 Fig. G U050 10-50R Fig. H U051F 10-50R, 5-20R2 Fig. M U061C (2) R32U Fig. O U501 6-50R 20 GFI 30 30 SPACE GFI Midwest Electric Products Power Outlets 54 Data subject to change without notice. Power Outlets Unmetered Surface, 60 – 100 Amps, 120/240V Fig. A U546 14-60R Fig. F U511G 6-50R, 5-20R2 Fig. G U666C010 10-30R, (2) 5-20R2GFCI Fig. H U058C BR54U, BR32U Fig. I U070C 10-50R, 7310, 5-20R2 Fig. B U041C R32U, 5-20R2 Fig. C U050C 10-50R Fig. D U361G (2) 5-20R2 Fig. E U511C 6-50R, 5-20R2 Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U546 14-60R — 60 G 6 x 9 Y — 5 4 N B U041C R32U, 5-20R2 CB130, CB120, Space CB120 70 K 6 x 14 LC33N7 10 Y2 C U050C 10-50R CB250, Space CB120 70 O 6 x 14 LC33N7 10 N D U361G (2) 5-20R2 GFI120 70 K 6 x 14 LC33N7 9 Y2 E U511C 6-50R, 5-20R2 CB250, CB120 70 K 6 x 14 LC33N7 10 Y2 F U511G 6-50R, 5-20R2 CB250, GFI120 70 K 6 x 14 LC33N7 10 Y2 G U666C010 10-30R, (2) 5-20R2GFCI CB230, (2) CB120, Space CB120 70 U 9 x 17 LC55N1 16 1 N H U058C1 BR54U, BR32U CB250, CB130 80 V 9 x 17 LC33N1 15 Y2 I U070C 10-50R, 7310, 5-20R2 CB250, CB220, CB120 90 U 9 x 17 LC55N1 16 N J U002C (2) 10-50R, 5-20R2 (2) CB250, CB120 100 U 14 x 21 LC55N1 31 N K U132CTL R32U CB130, Space (2) CB120 100 V 9 x 17 LC33N1T 11 Y2 L U014C0103 (4) 5-20R2GFCI (4) CB120, Space CB120 100 U 9 x 17 LC55N1 28 Y2 M U061CTL (2) R32U (2) CB130, Space CB120 100 O 9 x 17 LC33N1T 14 Y2 N U075C BR54U, R32U, 5-20R2 CB250, CB130, CB120, Space CB120 100 U 9 x 17 LC55N1 16 Y2 O U354C BR54U CB250, Space (3) CB120 100 V 9 x 17 LC55N1 16 Y2 P U614C1 (2) R32U, (2) BR32U (4) CB130, Space CB120 100 V 14 x 21 LC55N1 30 Y2 1 Model number is also suitable for use as temporary site service equipment when installed in accordance with the NEC. 2 cULus approved. 3 Earth Burial Model U014CP6010. * Wire Range Table on page 63. 50 20 GFI 30 SPACE 20 20 SPACE 30 20 GFI GFI SPACE 50 20 50 30 GFI SPACE SPACE 50 20 20 GFI 50 20 Fig. J U002C (2) 10-50R, 5-20R2 Fig. K U132CTL R32U Fig. M U061CTL (2) R32U Fig. O U354C BR54U Fig. L U014C010 (4) 5-20R2GFCI Fig. N U075C BR54U, R32U, 5-20R2 Fig. P U614C (2) R32U, (2) BR32U 50 50 20 SPACE 30 SPACE 20 20 20 20 GFI GFI GFI GFI SPACE 30 30 SPACE 30 20 SPACE 50 SPACE SPACE SPACE 50 30 30 30 30 SPACE Midwest Electric Products Power Outlets 55 Data subject to change without notice. Power Outlets Unmetered Surface, 120 – 200 Amps, 120/240V Metered Surface, 80 – 100 Amps, 120V/240V Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening Load & Neutral Bar Unit Wt. Std Pkg. UL A U004CTL010 (2) BR54U, 5-20R2GFCI (2) CB250, CB120 120 U 9 x 17 Y LC55N1T 17 1 Y1 B U004F (2) BR54U, 5-20R2 FH2 120 U 14 x 21 FR64X2 30 C U870G6 L6-30R, (2) L5-20R GFI230, (2) GFI120, Space CB120 125 Q 9 x 21 LC1212PC 16 D U239G L6-30R, (2) L5-20R GFI230, (2) GFI120 200 N 14 x 21 LC1212PC 30 1 cULus approved. * Wire Range Table on page 63. Fig. Model Number Receptacles Circuit Protection Amps Wire Range* Cabinet Size Hub Opening |
版權(quán)聲明:以上所展示的信息由會(huì)員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會(huì)員負(fù)責(zé)。機(jī)電之家對(duì)此不承擔(dān)任何責(zé)任。 友情提醒:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。 |
機(jī)電之家網(wǎng) - 機(jī)電行業(yè)權(quán)威網(wǎng)絡(luò)宣傳媒體
關(guān)于我們 | 聯(lián)系我們 | 廣告合作 | 付款方式 | 使用幫助 | 會(huì)員助手 | 免費(fèi)鏈接Copyright 2025 jdzj.com All Rights Reserved??技術(shù)支持:機(jī)電之家 服務(wù)熱線:0571-87774297
網(wǎng)站經(jīng)營許可證:浙B2-20080178