FSL100 火焰探測器 FSL100 Series Flame Detectors UV, UVIR, IR3 The FSL100 Series of flame detectors from Honeywell delivers robust, fast and reliable detection of flaming fires in a wide range of applications.
The range consists of UV, UVIR and IR3 flame detectors. All utilise sophisticated sensing and signal analysis to detect fires quickly while also rejecting false alarms. The FSL100 may be small and lightweight for easy installation but they are designed to work in tough environments both in and out of doors as well as potentially explosive atmospheres.
With a large field of view they can detect a range of different types of fire including hydrocarbon and non hydrocarbon sources. Available in UV, UVIR and 3IR we have your application covered.
Suitable for Many Applications ? UV, UVIR and IR3 available ? Hydrocarbon and non hydrocarbon sources ? Use in potentially explosive atmospheres ? Indoor and outdoor operation ? High visibility red or discrete white models available Great Performance ? Approved to EN54-10 and FM3260 flame detector standards ? Comprehensive automatic self test ? Remote manual self test option Fast & Reliable ? High speed sensors and microprocessor ? Sophisticated analysis algorithms ? Continuous health monitoring ? False alarm rejection Reduced Life Cost ? Long life elements ? Pressure compensation to avoid contamination ? 2 year warranty ? Buy with confidence Ease of Installation and Use ? Relay and mA outputs as standard ? Lightweight GRP housing ? Pre-formed knockouts ? Optional swivel mounting bracket ? Long range test lamp available
UV, UV/IR, IR3 Flame Detectors
FSL100-UV
? Suitable for indoor applications, for example fume hoods and hydrogen storage areas ? Effective solution for materials burning with low temperatures, e.g. Sulphur ? Detects fires caused by higher hydrocarbons (wood, paper, petrol) as well as hydrogen and lower hydrocarbons such as methanol and methane ? Good resistance against the influences of: - Direct and reflected sunlight - Artificial light, such as fluorescent tubes and glass covered halogen lamps
FSL100-UVIR ? Analysis of the flame flicker-frequency for improved false alarm rejection ? Dual sensing methodology enables a wide range of hydrocarbon and non-hydrocarbon fires to be effectively detected ? Monitors higher hydrocarbons flames (wood, paper, petrol) but also hydrogen and lower hydrocarbons such as methanol and methane ? Good resistance against the influences of: - Direct and reflected sunlight - Artificial light, such as fluorescent tubes and glass covered halogen lamps - Arcs and electric discharges (static or from e.g. electric motors) - The radiation from electric welding provided that the electric welding takes place at a distance more than 3 meters from the flame detector (a welding rod contains organic compounds which show flame phenomena)
FSL100-IR3 ? Analysis of the flame flicker frequency for improved false alarm rejection ? Particularly suited to liquid hydrocarbon and dirty fires ? Affected less by window contamination or smoky fires ? Detects higher hydrocarbons flames (wood, paper, petrol) and lower hydrocarbons such as methanol and methane ? Good resistance against the influences of: - Direct and reflected sunlight - Artificial light, such as fluorescent tubes and glass covered halogen lamps - Arcs and electric discharges (static or from e.g. electric motors) - The radiation from electric welding provided that the electric welding takes place at a distance more than 3 meters from the flame detector (a welding rod contains organic compounds which show flame phenomena) ? Especially suitable for smoky fires. Analysis of the flame flicker frequency for improved false alarm rejection
Specifications: FSL100 Series Flame Detectors
Ordering Information Part Number Description FSL100-UV (red housing) UV flame detector FSL100-UV-W (white housing) Suitable for ATEX zone 2/22; FM 3611 Class 1, 2 & 3 Div 2 EN54-10 (HIGH sensitivity) certificate FM3260 approval (pending*) FSL100-UVIR (red housing) UV/IR flame detector FSL100-UVIR-W (white housing) Suitable for ATEX zone 2/22; FM 3611 Class 1, 2 & 3 Div 2 EN54-10 (HIGH sensitivity) certificate FM3260 approval (pending*) FSL100-IR3 (red housing) Triple IR flame detector FSL100-IR3-W (white housing) Suitable for ATEX zone 2/22; FM 3611 Class 1, 2 & 3 Div 2 EN54-10 (HIGH sensitivity) certificate FM3260 approval (pending*) FSL100-SM21 Swivel mount (White) FSL100-TL FSL100 test lamp, incl. universal charger and carrying case; safe areas only FSL100-TLX FSL100 test lamp, incl. carrying case; intrinsically safe; hazardous area
上海宛暢實業(yè)有限公司是一家自動化設(shè)備及工業(yè)零部件的專業(yè)供應(yīng)商.公司成立于2012年,專注于為石油,化工,電力,鋼鐵,制藥,環(huán)保等領(lǐng)域終端用戶提供工程配套自動化設(shè)備及工控備件. 公司依托國內(nèi)外一批成熟大客戶:中海油渤海鉆井平臺,山東瑞星化工,河北沙河電廠,PAKISTAN NATIONAL REFINERY LIMITED,Petro Oil Supply SDN BHD,THUSO MOLOSIWA BOTSWANA POWER CORPORATION,巴西PAMPA1X345MW燃煤電站等,擁有一批非常優(yōu)勢的品牌資源. 主營:Honeywell霍尼韋爾氣體探測,Micro Motion艾默生高準(zhǔn)質(zhì)量流量計,羅斯蒙特變送器,霍尼韋爾控制系統(tǒng)與集成,燃燒控制產(chǎn)品,環(huán)境自控,閥門執(zhí)行器、開關(guān)等。 #上海宛暢實業(yè)有限公司#專業(yè)銷售歐美日韓進口的工控產(chǎn)品、儀器儀表等工控備件! 原裝進口、型號全、價格優(yōu),歡迎詢價! |
版權(quán)聲明:以上所展示的信息由會員自行提供,內(nèi)容的真實性、準(zhǔn)確性和合法性由發(fā)布會員負責(zé)。機電之家對此不承擔(dān)任何責(zé)任。 友情提醒:為規(guī)避購買風(fēng)險,建議您在購買相關(guān)產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。 |
機電之家網(wǎng) - 機電行業(yè)權(quán)威網(wǎng)絡(luò)宣傳媒體
關(guān)于我們 | 聯(lián)系我們 | 廣告合作 | 付款方式 | 使用幫助 | 會員助手 | 免費鏈接Copyright 2025 jdzj.com All Rights Reserved??技術(shù)支持:機電之家 服務(wù)熱線:0571-87774297
網(wǎng)站經(jīng)營許可證:浙B2-20080178