N9020B-503
|
Frequency Range, 10 Hz to 3.6 GHz
-
Frequency Range: 10 Hz to 3.6 GHz
|
N9020B-508
|
Frequency Range, 10 Hz to 8.4 GHz
-
Frequency Range: 10 Hz to 8.4 GHz
-
Available as a post-purchase upgrade
|
N9020B-513
|
Frequency Range, 10 Hz to 13.6 GHz
-
Frequency Range: 10 Hz to 13.6 GHz
-
Available as a post-purchase upgrade
|
N9020B-526
|
Frequency Range, 10 Hz to 26.5 GHz
-
Frequency Range: 10 Hz to 26.5 GHz
-
Available as a post-purchase upgrade
|
N9020B-532
|
Frequency Range, 10 Hz to 32 GHz
-
Frequency Range: 10 Hz to 32 GHz
|
N9020B-544
|
Frequency Range, 10 Hz to 44 GHz
-
Frequency Range: 10 Hz to 44 GHz
|
N9020B-550
|
Frequency Range, 10 Hz to 50 GHz
-
Frequency Range: 10 Hz to 50 GHz
|
|
Preamplifier
|
N9020B-P03
|
Preamplifier, 3.6 GHz
-
20 dB gain
-
–166 dBm DANL with preamp
-
Preamplifier for enhanced ability to detect low-level signals
-
Available as a post-purchase upgrade
|
N9020B-P08
|
Preamplifier, 8.4 GHz
-
35 dB gain
-
–166 dBm DANL with preamp (3.6 to 8.4 GHz)
-
Preamplifier for enhanced ability to detect low-level signals
-
Available as a post-purchase upgrade
|
N9020B-P13
|
Preamplifier, 13.6 GHz
-
35 dB gain
-
-165 dBm DANL with preamp (3.6 to 13.6 GHz)
-
Preamplifier for enhanced ability to detect low-level signals
-
Available as a post-purchase upgrade
|
N9020B-P26
|
Preamplifier, 26.5 GHz
-
35 dB gain
-
–157 dBm DANL with preamp (20 to 26.5 GHz)
-
Preamplifier for enhanced ability to detect low-level signals
-
Available as a post-purchase upgrade
|
N9020B-P32
|
Preamplifier, 32 GHz
-
40 dB gain
-
-161 dBm DANL with preamp (26.5 to 32 GHz)
-
Preamplifier for enhanced ability to detect low-level signals
|
N9020B-P44
|
Preamplifier, 44 GHz
-
40 dB gain
-
-155 dBm DANL with preamp (40 to 44 GHz)
-
Preamplifier for enhanced ability to detect low-level signals
|
N9020B-P50
|
Preamplifier, 50 GHz
-
40 dB gain
-
-153 dBm DANL with preamp (46 to 50 GHz)
-
Preamplifier for enhanced ability to detect low-level signals
|
|
Bandwidth
|
N9020B-B1A
|
Analysis Bandwidth, 125 MHz
-
Capture memory: 4 GB
-
ADC resolution: 14 bits
-
Available as a post-purchase upgrade
|
N9020B-B1X
|
Analysis Bandwidth, 160 Mhz
-
Capture memory: 4 GB
-
ADC resolution: 14 bits
-
Supports real-time spectrum analyzer
-
Available as a post-purchase upgrade
|
N9020B-B40
|
Analysis Bandwidth, 40 MHz
-
Capture memory: 2 GB
-
ADC resolution: 16 bits
-
Available as a post-purchase upgrade
|
N9020B-B85
|
Analysis Bandwidth, 85 MHz
-
Capture memory: 4 GB
-
ADC resolution: 14 bits
-
Available as a post-purchase upgrade
|
|
Performance Options
|
N9020B-FT2
|
Frequency Mask Trigger, Optimum Detection License
-
Capture elusive, intermittent signals for further analysis
-
> 3.6 ?s signal duration
-
Seamless operation in 89600 VSA Software and N9067C pulse application
-
Available as a post-purchase upgrade
|
N9020B-MPB
|
Microwave Preselector Bypass
-
Excellent wideband amplitude flatness and phase linearity
-
Improve measurement repeatability in the higher bands
-
Increased IF output bandwidth
-
Available as a post-purchase upgrade
|
N9020B-NF2
|
Noise Floor Extension
-
License key enabled for improvement in analyzer noise floor
-
Feature is enabled or disabled for spectrum analysis with a keystroke
-
Works with all spectrum measurements
-
Available as a post-purchase upgrade
|
N9020B-PFR
|
Precision Frequency Reference
-
Enhances the frequency reference performance and stability
-
Temperature stability: ±1.5 x 10-8
-
One year aging rate: ±1 x 10-7
-
Residual FM: 0.25 Hz x N p-pin 20 ms
-
Available as a post-purchase upgrade
|
N9020B-TDS
|
Time Domain Scan
-
~90% overlap in the time domain for amplitude accuracy and fast transient capture
-
CISPR-compliant amplitude accuracy and weighted detector performance
-
Monitor spectrum and amplitude probability distribution
-
Available as a post-purchase upgrade
|
N9020B-DP2
|
Deep Capture Memory
-
Digital processor with 2 GB capture memory
-
Improves IQ acquisition speed
-
25 MHz analysis bandwidth
-
Enables fast sweep capability
-
Available at time of purchase only
|
N9020B-EA3
|
Electronic Attenuator, 3.6 GHz, Upgrade
-
Step size: 1 dB
-
Range: 0 to 24 dB
-
Full range including mechanical attenuation 94 dB
-
Available as a post-purchase upgrade
|
N9020B-EDP
|
Enhanced Display Package License
-
Spectrogram: Time, amplitude, frequency and delta markers
-
Trace Zoom: Both traces active, lower trace a subset of upper trace
-
Zone Span: One trace updated at a time, independent bandwidths, point and sweep time
-
Available as a post-purchase upgrade
|
N9020B-EMC
|
Basic EMC Functionality License
-
CISPR 16-1-1 (2010) fully-compliant detectors
-
CISPR band presets to 18 GHz
-
Measure at marker with three detectors
-
Tune and listen for signal discrimination
-
Available as a post-purchase upgrade
-
See FAQ's for the differences between option EMC and the N6141C EMI measurement application
|
N9020B-FP2
|
Fast Power, Up To 40 MHz Bandwidth
-
Enables hardware accelerated fast power measurement
-
Single acquisition bandwidth: 40 MHz
-
Optimized for power measurements such as Channel Power, Adjacent Channel Power, Occupied Bandwidth and Harmonic measurements
-
Available as a post-purchase upgrade
|
N9020B-FT1
|
Frequency Mask Trigger, Basic Detection License
-
Capture elusive, intermittent signals for further analysis
-
> 15 ?s signal duration
-
Seamless operation in 89600 VSA Software and N9067C pulse application
-
Available as a post-purchase upgrade
|
N9020B-RBE
|
Resolution Bandwidth Extended
-
Enable resolution bandwidth up to 133 MHz in the Spectrum Analyzer mode and Zero Span sweep type
-
Enhanced ability for band-limited gapless power monitoring over long time periods
-
Requires option B85, B1A, or B1X
-
Available as a post-purchase upgrade
|
|
Baseband Inputs
|
N9020B-BBA
|
I/Q Baseband Inputs, Analog
-
Input impedance: Selectable 50 ohm and 1 Mohm
-
Baseband bandwidth: 10 MHz standard/optional 25 MHz or 40 MHz
-
Baseband capture memory: 500 MSamples (2 GB) standard
-
ADC resolution: 16 bits
-
Available as a post-purchase upgrade
|
|
Calibration Options
|
N9020B-AMG
|
Calibration + Uncertainties + Guardbanding (Accredited)
-
Ships from the factory with ISO 17025 calibration
-
Provides measurement results, uncertainties and specifications with guardbands
-
Uncertainties are not included in the determination of the pass/fail status
-
Available at time of purchase only
|
N9020B-A6J
|
ANSI Z540-1-1994 Calibration
-
Ships from the factory with ANSI Z540 calibration
-
Provides measurement results, uncertainties and specifications
-
Uncertainties are not included in the determination of the pass/fail status
-
Available at time of purchase only
|
N9020B-UK6
|
Commercial Calibration Certificate with Test Data
-
Commercial calibration performed by a Keysight factory (new instruments only)
-
Printed copy of the calibration certificate
-
Instructions to download the test data report from Infoline
-
Available at time of purchase only
|
|
Connection Options
|
N9020B-CR3
|
Connector, Wideband IF Output
-
IF output bandwidth up to 410 MHz with preselector bypassed
-
For low band, IF output bandwidth up to 140 MHz
-
Connector: SMA female, 50-ohm impedance nominal
-
Available as a post-purchase upgrade
|
N9020B-CRP
|
Connector, Programmable Rear IF Output
-
Frequency of the IF output is adjustable from 10 to 75 MHz, in 500 kHz steps
-
IF output bandwidth is 100 MHz nominal at 70 MHz center frequency
-
Connector type: SMA (female), 50-ohm impedance nominal
-
Available as a post-purchase upgrade
|
N9020B-YAS
|
Y-Axis Ouptut
-
Outputs the screen video similar to what is viewed on the display
-
Operates in spectrum analyzer mode only
-
Connector type: BNC (female), 50-ohm impedance nominal
-
Available as a post-purchase upgrade
|
|
External Mixing
|
N9020B-EXM
|
External Mixing
-
Analyze signals up to 110 GHz
-
Amplitude corrections for conversion loss
-
Signal identification, mixer biasing (-5 mA to +5 mA)
-
Supports 89600 VSA software
-
Available as a post-purchase upgrade
|
|
Real time signal analysis
|
N9020B-RT1
|
Real-time analysis up to maximum available BW, basic detection license
|
N9020B-RT2
|
Real-time analysis up to maximum available BW, optimum detection, license
|
|
Portable Packaging
|
N9020B-PRC
|
Portable Configuration
-
Rubber protective corners and end guards
-
Pivoting side-mounted carrying handle
-
Available as a post-purchase upgrade
|
|
Security - PC features
|
N9020B-SF2
|
Security Features, Prohibit Saving Results
-
Restricts ability to save measurement results or user configuration to improve security
-
Prohibits saving results or setups to solid state drive
-
Instrument softkeys and SCPI commands eliminate the ability to save or recall user data
-
Available as a post-purchase upgrade
|
N9020B-SSD
|
Additional Removable Solid State Drive
-
Rugged removable bay, minimum 1,500 insertion cycles
-
Fully imaged with the operating system, MXA instrument software, instrument-specific alignment files
-
Available as a post-purchase upgrade
|
N9020B-SF1
|
Security Features, Exclude Launching Programs
-
Ability to limit menu selections and SCPI commands to improve instrument security
-
Prevent the launching of Windows programs from the instrument application
-
Reduce the instrument’s vulnerability to the effects of unauthorized or undesirable third-party programs or scripts
-
Available as a post-purchase upgrade
|
N9020B-SS1
|
Additional removable solid state drive, Win10
|
|
Source Connectivity
|
N9020B-ESC
|
External Source Control License
|