General specifications
|
Effective detection range
|
0 ... 7 m
|
Threshold detection range
|
9 m
|
Light source
|
LED red
|
Light type
|
modulated visible red light
|
Polarization filter
|
yes
|
Functional safety related parameters
|
MTTFd
|
803 a
|
Mission Time (TM)
|
20 a
|
Diagnostic Coverage (DC)
|
0 %
|
Indicators/operating means
|
Function indicator
|
LED yellow: switching state
LED red: pre-fault indication
|
Control elements
|
Sensing range adjuster, light-on/dark-on changeover switch
|
Control elements
|
switch for timer function
|
Electrical specifications
|
Operating voltage
|
12 ... 240 V DC
24 ... 240 V AC (50 ... 60 Hz)
|
Output
|
Switching type
|
light/dark on
|
Signal output
|
1 relay output
|
Compliance with standards and directives
|
Directive conformity
|
EMC Directive 2004/108/EC
|
|
EMC Directive 2004/108/EC
|
EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007+A1:2012
|
Standard conformity
|
|
|
Product standard
|
EN 60947-5-2:2007
IEC 60947-5-2:2007
|
Approvals and certificates
|
EAC conformity
|
TR CU 020/2011
TR CU 004/2011
|
Approvals
|
CE
|
Mechanical specifications
|
Housing width
|
25 mm
|
Housing height
|
64 mm
|
Housing depth
|
75 mm
|
Degree of protection
|
IP67
|
Connection
|
terminal compartment PG9, ≤ 2.5 mm2
|
Material
|
|
|
Housing
|
PBT
|
|
Optical face
|
PMMA
|