YJV電力電纜優(yōu)質(zhì)廠家供應(yīng)商
截 面
(mm2)
|
0.6/1KV(A) θn=90℃
|
6/6KV~8.7/10KV(A) θn=90℃
|
26/35KV(A) θn=80℃
|
4 芯
|
單芯θn=30℃
|
3 芯
|
單芯θn=30℃
|
3芯
|
單芯θn=30℃
|
20℃
|
25℃
|
30℃
|
|
|
|
20℃
|
25℃
|
30℃
|
|
|
|
25℃
|
|
|
鋁
芯
|
4
|
42
|
40
|
38
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
47
|
45
|
43
|
|
|
|
|
|
|
|
|
|
|
|
|
10
|
62
|
60
|
58
|
|
|
|
|
|
|
|
|
|
|
|
|
16
|
83
|
80
|
77
|
|
|
|
|
|
|
|
|
|
|
|
|
25
|
104
|
100
|
96
|
|
|
|
109
|
105
|
101
|
|
|
|
|
|
|
35
|
125
|
120
|
115
|
|
|
|
130
|
125
|
120
|
|
|
|
|
|
|
50
|
146
|
140
|
134
|
|
|
|
151
|
145
|
139
|
|
|
137
|
|
|
|
70
|
182
|
175
|
168
|
|
|
|
187
|
180
|
173
|
215
|
205
|
172
|
|
|
|
95
|
218
|
210
|
202
|
|
|
|
224
|
215
|
206
|
255
|
235
|
206
|
|
|
|
120
|
244
|
235
|
226
|
|
|
|
255
|
245
|
235
|
280
|
265
|
224
|
|
|
|
150
|
276
|
265
|
254
|
|
|
|
286
|
275
|
264
|
320
|
305
|
243
|
|
|
|
185
|
317
|
305
|
293
|
|
|
|
322
|
310
|
298
|
350
|
335
|
|
|
|
|
240
|
369
|
355
|
341
|
|
|
|
374
|
360
|
346
|
400
|
390
|
|
|
|
|
300
|
|
|
|
|
|
|
416
|
400
|
384
|
440
|
430
|
|
|
|
|
400
|
|
|
|
|
|
|
|
|
|
505
|
515
|
|
|
|
|
500
|
|
|
|
|
|
|
|
|
|
555
|
575
|
|
|
|
|
630
|
|
|
|
|
|
|
|
|
|
610
|
640
|
|
|
|
|
銅
芯
|
4
|
52
|
50
|
48
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
62
|
60
|
58
|
|
|
|
|
|
|
|
|
|
|
|
|
10
|
83
|
80
|
77
|
|
|
|
|
|
|
|
|
|
|
|
|
16
|
104
|
100
|
96
|
|
|
|
|
|
|
|
|
|
|
|
|
25
|
135
|
130
|
125
|
|
|
|
140
|
135
|
130
|
|
|
|
|
|
|
35
|
161
|
155
|
149
|
|
|
|
166
|
160
|
154
|
|
|
|
|
|
|
50
|
192
|
185
|
178
|
|
|
|
198
|
190
|
182
|
|
|
|
|
|
|
70
|
234
|
225
|
216
|
|
|
|
239
|
230
|
221
|
270
|
260
|
177
|
|
|
|
95
|
281
|
270
|
259
|
|
|
|
286
|
275
|
264
|
320
|
300
|
221
|
|
|
|
120
|
317
|
305
|
293
|
|
|
|
322
|
310
|
298
|
355
|
340
|
267
|
|
|
|
150
|
359
|
345
|
331
|
|
|
|
364
|
350
|
336
|
390
|
385
|
288
|
|
|
|
185
|
406
|
390
|
374
|
|
|
|
411
|
395
|
379
|
430
|
430
|
313
|
|
|
|
240
|
473
|
455
|
437
|
|
|
|
473
|
455
|
437
|
490
|
490
|
|
|
|
|
300
|
|
|
|
|
|
|
536
|
515
|
494
|
535
|
550
|
|
|
|
|
400
|
|
|
|
|
|
|
|
|
|
595
|
570
|
|
|
|
|
500
|
|
|
|
|
|
|
|
|
|
655
|
630
|
|
|
|
|
630
|
|
|
|
|
|
|
|
|
|
710
|
765
|
|
YJV電力電纜優(yōu)質(zhì)廠家供應(yīng)商
適用范圍 Applications
本產(chǎn)品適用于工頻額定電壓3.6/6kv~26/35kv輸配電線路作配送電能子用。
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
使用特性 Operating characteristics
· 工頻額定電壓U0/U為3.6/6kv~26/35kv。
Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
· 電纜導(dǎo)體的最高允許工作溫度:90℃。
Max.admissible operating temperature of the conductor:90℃.
· 短路時(shí)(最長(zhǎng)時(shí)間不超過(guò)5s)電纜導(dǎo)體的最高溫度不超過(guò)2500C。
Max. short-circurt temperature of conductor shall not exceed 2500C.
(5s maximum duration)
· 電纜敷設(shè)時(shí)環(huán)境溫度應(yīng)不低于00C。
The ambient temperature under installation should not below 00C.
· 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a single-core cable should not less than 15 times of the cable diameter.
電纜額定電壓的選擇 Voltage designation
· 電纜的額定電壓應(yīng)適合于電纜系統(tǒng)的運(yùn)行狀況,用U0/U(Um)kv表示。
U0-電纜設(shè)計(jì)用的導(dǎo)體對(duì)地或金屬屏蔽之間的額定工頻電壓;
U-電纜設(shè)計(jì)用的導(dǎo)體間的額定工頻電壓;
Um-設(shè)備可承受的“最高系統(tǒng)電壓”的最大值。
The rated voltage of the cable for a given applixation shall be suitable for the operating conditions
in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv
Where:
U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed;
U - The rated power-frequency voltage between conductos, for which the cable designed;
Um- The maximum value of the“highest system voltage”for which the equipment may beused.
· 三相系統(tǒng)用電纜的U0值推薦如下表:
The values of U0 recommened for cable to be used in three-phase systems are listed below:
|
U kv
|
U m kv
|
U 0 * kv
|
A 和 B 類系統(tǒng) System categories A and B
|
C 類系統(tǒng) Systems categories C
|
6
|
7.2
|
3.6
|
6
|
10
|
12
|
6
|
8.7
|
15
|
17.5
|
8.7
|
12
|
20
|
24
|
12
|
18
|
30
|
36
|
18
|
-
|
35
|
40.5
|
21
|
26
|
|
A類系統(tǒng)──該類系統(tǒng)任何一相導(dǎo)體與地和接地導(dǎo)體接觸時(shí),能在1min內(nèi)與系統(tǒng)分離
B類系統(tǒng)──該類系統(tǒng)僅包括單相接地故障短時(shí)運(yùn)行的條件,接地故障時(shí)間應(yīng)不超過(guò)1h, 但在任何情況下,最長(zhǎng)不超過(guò)8h每年接地故障總持續(xù)時(shí)間不超過(guò)125h;
C類系統(tǒng)──不屬于A類、B類的系統(tǒng)。
System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min.
System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h.
System categeory C──This category comprises all systems which do not fall into A and B
|
YJV電力電纜優(yōu)質(zhì)廠家供應(yīng)商
|