Technical details
Connection G1/4, Namur
Nominal size 6 mm
Temperature range -10°C ... +70°C
Medium Filtered, oil-free and dried compressed air according to ISO
8573-1:2010, Class 7:2:4, instrument air, free of aggressive
additives. Alternatively the pressure dew point must be at
least 10°C below lowest occurring ambient temperature.
Materials Body: Al (anodized), plastic, seals: NBR and POM, inner
parts: Al, steel rostfrei and brass
Protection IP 65 according to EN 60529
Valves in accordance with 2014/34/EU (ATEX) available. (page 7)
5/2- and 5/3-way-valves
MN-06-510-HN-xxx
5/2-way, single solenoid, air spring
return
MN-06-511-HN-xxx
5/2-way, single solenoid, mechanical
spring return
MN-06-520-HN-xxx
5/2-way, double solenoid
MN-06-530-HN-xxx
5/3-way, center position closed
Electrical options
Nominal voltage Power consumption Specifics Plug connection*1 -xxx
12 V DC 4.2 W Form B industrial norm -441
12 V DC 2.2 W max. 8 bar Form B industrial norm -461
24 V DC 4.2 W Form B industrial norm -442
24 V DC 4.2 W M 12 -O42
24 V DC 2.2 W max. 8 bar Form B industrial norm -462
24 V DC 2.5 W max. 8 bar M 12 -O62
24 V AC 7/4 VA Form B industrial norm -452
115 V AC 7/4 VA Form B industrial norm -456
230 V AC 7/4 VA Form B industrial norm -457
*1 Plug socket not included, suitable plug sockets see page 3.
14 4 2
5 1 3
14 4 2
5 1 3
14 4 2 12
5 1 3
4 2
5 1 3
14 12
02 Subject?to?change
Valves > standardized valves > electrically operated >
Series MN-06
NAMUR
Model-no.: MN-06-310 MN-06-311 MN-06-510 MN-06-511 MN-06-520 MN-06-530
Operating pressure* (bar) 2...10 3...10 2...10 3...10 2...10 3...10
Pilot pressure* (bar) 2...10 3...10 2...10 3...10 2...10 3...10
Flow rate (Nl/min) 750 750 750 750 750 650
Response time (ms)
at 6 bar
on: 13
off: 16
on: 13
off: 16
on: 13
off: 16
on: 13
off: 16
on: 12
off: 12
on: 13
off: 15
Weight (kg) 0.320 0.320 0.320 0.320 0.460 0.460
* max. 8 bar at 2.2 W and 2.5 W
Technical data
Dimensions
M-04-310-HN. MO-04-310-HN MN-06-31x-HN
M-04-310-HN, MO-04-310-HN MN-06-51x-HN MN-06-520-HN, MN-06-530-HN
137
25
3
? 5.5
128
3 1
45
32
70.5
1 = pressure inlet
2,4 = outlets
3,5 = exhausts
24
2
183
202
44
137
25
24 ? 5.5
128
5 1
45
32
70.5
22 22
3
4 2
Plug socket (not included in scope of delivery) can be repositioned by 180°.
Solenoid coil can be repositioned by 4 x 90°