SCONINC變換器SCONI-2400-B16Y,出售云永WYPA3040T220CONVEX康柏斯CSDL-02AP0 CSDL-02AP1
CONVEX康柏斯CSDL-02BP0 CSDL-02BP1
CONVEX康柏斯CSDL-02AS0 CSDL-02AS1
CONVEX康柏斯CSDL-02BS0 CSDL-02BS1
CONVEX康柏斯CSDL-02AT0 CSDL-02AA1
CONVEX康柏斯CSDL-02BT0 CSDL-02BT1
CONVEX康柏斯CSDL-04AA0 CSDL-04AA1
CONVEX康柏斯CSDL-04BA0 CSDL-04BA1
CONVEX康柏斯CSDL-04AP0 CSDL-04AP1
CONVEX康柏斯CSDL-04BP0 CSDL-04BP1
CONVEX康柏斯CSDL-04AS0 CSDL-04AS1
CONVEX康柏斯CSDL-04BS0 CSDL-04BS1
CONVEX康柏斯CSDL-04AT0 CSDL-04AA1
CONVEX康柏斯CSDL-04BT0 CSDL-04BT1
CONVEX康柏斯CSDL-08AA0 CSDL-08AA1
CONVEX康柏斯CSDL-08BA0 CSDL-08BA1
CONVEX康柏斯CSDL-08AP0 CSDL-08AP1
CONVEX康柏斯CSDL-08BP0 CSDL-08BP1
CONVEX康柏斯CSDL-08AS0 CSDL-08AS1
CONVEX康柏斯CSDL-08BS0 CSDL-08BS1
CONVEX康柏斯CSDL-08AT0 CSDL-08AA1
CONVEX康柏斯CSDL-08BT0 CSDL-08BT1
CONVEX康柏斯CSDL-15AA0 CSDL-15AA1
CONVEX康柏斯CSDL-15BA0 CSDL-15BA1
CONVEX康柏斯CSDL-15AP0 CSDL-15AP1
CONVEX康柏斯CSDL-15BP0 CSDL-15BP1
CONVEX康柏斯CSDL-15BS0 CSDL-15BS1
CONVEX康柏斯CSDL-15AT0 CSDL-15AA1
CONVEX康柏斯CSDL-15BT0 CSDL-15BT1
退磁檢查電流互感器在電流突然下降的情況下,互感器鐵芯可能產(chǎn)生剩磁。如電流互感器在大電流情況下突然切斷電源、二次繞組突然開路等;ジ衅麒F芯有剩磁,使鐵芯磁導率下降,影響互感器性能。長期使用后的互感器都應該退磁;ジ衅鳈z驗前也要退磁。退磁就是通過一次或二次繞組以交變的勵磁電流,給鐵芯以交變的磁場。從0開始逐漸加大交變的磁場(勵磁電流)使鐵芯達到飽和狀態(tài),然后再慢慢減小勵磁電零,以剩磁。對于電流互感器退磁,一次繞組開路,二次繞組通以工頻電流,從零開始逐漸到一定的電流值(該電流值與互感器的設計測量上限有關,一般為額定電流的20-50%左右?梢噪娏骰ジ衅麟娏骰ジ衅鬟@樣判斷,如果電流突然急劇變大。其動合觸點應無抖動地閉合。c.當無外來碰撞和振動,繼電器的整定值整定在銘牌中部(或大于中部整定值)時,過電壓繼電器激勵量為整定電壓的0.6倍,繼電器的動斷觸點應可靠地閉合,動合觸點應可靠地斷開;低電壓繼電器激勵量不低于整定電壓的1.5倍,繼電器的動斷觸點應可靠地斷開,在0.6倍的整定電壓(或更低)時,繼電器的動斷觸點應可靠地閉合。10.觸點性能a.觸點斷開容量:在直流有感(τ5ms)回路,U≤250V,I≤2A,為50W;在交流(cosφ0.4)回路,U≤250V,I≤2A,為250VA。b.電壽命:5×10次。c.機械壽命為10次。3.調(diào)試1.繼電器在使用前應檢查有無在運輸中產(chǎn)生的損壞。
CONVEX康柏斯CSDL-15AA0 Linear Servo AC(220V) CSDL 1.5KW 2.2kg
CONVEX康柏斯CSDL-08AA0 Linear Servo AC(220V) CSDL 800W 1.6kg
CONVEX康柏斯CSDL-04AA0 Linear Servo AC(220V) CSDL 400W 1.1kg
CONVEX康柏斯CSDL-02BA0 Linear Servo AC(220V) CSDL 200W 0.9kg
CONVEX康柏斯CSDM-A4TP0 Rotary Servo(Low Voltage) DC(24V) CSDH 40W 0.5kg
CONVEX康柏斯CSDM-A2TP0 Rotary Servo(Low Voltage) DC(24V) CSDH 26W 0.5kg
CONVEX康柏斯CSDM-A1TP0 Rotary Servo(Low Voltage) DC(24V) CSDH 16W 0.5kg
CONVEX康柏斯CSDH-15AA1 Rotary Servo AC(220V) CSDH 1.0KW 2.2kg
CONVEX康柏斯CSDH-10AA1 Rotary Servo AC(220V) CSDH 1.0KW 2.2kg
CONVEX康柏斯CSDH-08AA1 Rotary Servo AC(220V) CSDH 750W 2.2kg
CONVEX康柏斯CSDH-04AA1 Rotary Servo AC(220V) CSDH 400W 1.1kg
CONVEX康柏斯CSDH-02BA1 Rotary Servo AC(220V) CSDH 200W 0.9kg
CONVEX康柏斯CSDH-01BA1 Rotary Servo AC(220V) CSDH 100W 0.9kg
CONVEX康柏斯CSDH-A5BA1 Rotary Servo AC(220V) CSDH 50W 0.9kg
b、低電壓繼電器:0.5倍整定值的時間不大于20m。返回系數(shù)a、過電壓繼電器返回系數(shù)為0.85~0.95;b、低電壓繼電器返回系數(shù)為1.02~1.12;返回時間:不大于27ms。3.靜態(tài)有源電壓繼電器靜態(tài)有源電壓繼電器用于發(fā)電機保護、變壓器保護和輸電線路保護裝置中,作為過電壓保護或低電壓閉鎖的啟動元件。本繼電器為集成電路靜態(tài)型繼電器,精度高、功耗小、時間短、返回系數(shù)高、整定直觀方便、范圍寬,且作為低電壓繼電器使用無抖動現(xiàn)象。有輔源電壓繼電器,輔助電源采用開關電源變換,85-265V交直流通用,工作范圍大,從1-450V均能可靠工作。4.靜態(tài)無源電壓繼電器電壓繼電器用于發(fā)電機、變壓器和輸電線的繼電保護裝置中。排污工作全部結束。水垢影響編輯鎂離子和酸式碳酸鹽。有碳酸鹽的生成。另外,形成鐵銹。由于銹垢的產(chǎn)生,換熱效果下降。使換熱效果失去作用。節(jié)約能源、設備的使用壽命。影響(1)壓縮機組的影響:由于冷卻水質(zhì)差,在冷卻器中形成的污垢熱阻大,使冷卻器不能正常運行,了壓縮機中每一級的進口、出口參數(shù)偏離,影響了級與級之間的匹配性能,了壓縮機的效率,了加工氣量,了機組的能耗,使機組的整體性能下降。終使空分裝置的產(chǎn)量下降,能耗,運行周期縮短和變工況調(diào)節(jié)范圍縮小。(2)冷凍機的影響:冷卻水形成的污垢熱阻大,使冷凍機中的冷凝器不能正常運行。冷媒的冷凝壓力、溫度升高,使冷凍機的制冷量下降,空氣出空冷塔進分子篩純化器的溫度升高。