SHINHO星河SHN-700-CIO-Y,出售云永WYMY2C201D4CREVIS,ST-1218,Digital Input 8 Points, Sink, TermiCREVIS,NAl, 12V / 24Vdc
CREVIS,ST-1214,Digital Input 4 Points, Sink, TermiCREVIS,NAl, 12V / 24Vdc
CREVIS,ST-112F,Digital Input 16 Points, Source, 20P Connector 5Vdc
CREVIS,ST-1124,Digital Input 4 Points, Source, TermiCREVIS,NAl, 5Vdc
CREVIS,ST-111F,Digital Input 16 Points,Sink, 20P Connector 5Vdc
CREVIS,NA-9286,EtherCAT Network Adapter, 252 bytes input and 252 bytes output
CREVIS,NA-9131,CC-Link Network Adapter, RX/RY 112 points and RWr/RWw 16 points
CREVIS,ST-1114,Digital Input 4 Points, Sink, TermiCREVIS,NAl, 5Vd
CREVIS,RT-9273,MODBUS Interface Module
CREVIS,RT-9261,R-Bus CAN Interface Module
CREVIS,RT-9222,PROFIBUS Interface Module
CREVIS,RT-7941,Field Power Isolator with Over Current Protection / ID Type
CREVIS,RT-7641,Field DiCREVIS,STributor, 5Vdc, 24Vdc, 48Vdc, 110Vac, 220Vac, ID Type
CREVIS,RT-7518,Power DiCREVIS,STributor, ID Type
CREVIS,RT-7511,Expansion Power Supply, Input 24Vdc, Output 1.0A/5Vdc
CREVIS,RT-7508,Power DiCREVIS,STributor
通道顯示值無任何變化。A、用萬用表在接線端子上測量是否正常;B、檢查通道模塊開關(guān)與類型是否設(shè)置正確;C、打開表殼,檢查通道電纜是否接好。通道測量數(shù)值不準。A、檢查通道參數(shù)設(shè)置中,類型的設(shè)定是否與實際接入類型一致;B、該通道模塊開關(guān)設(shè)定是否與該通話類型相一致;C、檢查接線是否正確,線纜是否良好;D、在確定上述沒有問題,重新標定儀表(注意源精度一定要高于0.1%)若儀表標定不正常(無法標定),或標定正常但通道測量仍不正常,請進與生產(chǎn)廠聯(lián)系。維修知識編輯在使用無紙記錄儀的時候,可能因為使用的時間過久或者我們的非正常操作有可能設(shè)備出現(xiàn)問題,那么在出現(xiàn)這種情況的時候就需要了解一些無紙記錄儀的基本原理。b)當I/Is2時,平均誤差不大于5%+30ms。整定起動電流整定:起動電流整定開關(guān)為左一組撥碼開關(guān)(共兩個),左面一個表示1,右面一個表示0.1。若其值為5和6,則其整定值為5.6A。注意其范圍為無輔助電壓產(chǎn)品2-9.9A,級差是0.1。反時限特性曲線K值整定:K值整定開關(guān)為左第三組撥碼開關(guān)(共二個),左邊一個為表示1級;右邊一個表示0.1級。本產(chǎn)品K值整定范圍為0.1~9.9,(舉例)比如其值設(shè)定為5.0,過流值設(shè)定為5.0,輸入實際電流為30A時那么它的延時時間為13.5秒,但其速斷倍數(shù)值應設(shè)定為6倍以上。速動倍數(shù)整定:速動倍數(shù)選擇開關(guān)為左組撥碼開關(guān)。
CREVIS,RT-7408,Shield Module, ID Type
CREVIS,RT-7241,Field DiCREVIS,STributor, Arbitrary 5Vdc,24Vdc,48Vdc,120Vac, 240Vac
CREVIS,RT-7188,Common for 5Vdc and 0Vdc
CREVIS,RT-7118,Common for 24Vdc
CREVIS,RT-7111,Expansion power Supply, Input 24Vdc / Output1.0A/5Vdc
CREVIS,RT-7108,Common for 0Vdc
CREVIS,RT-7008,Shield Module
CREVIS,RT-5521,2 - Phase Bipolar CREVIS,STepping Motor Driver, 24Vdc 2A)
CREVIS,RT-5114,4 channels High Speed Counter Input, 24Vdc
CREVIS,RT-5112,2 channels High Speed Counter Input, 24Vdc
CREVIS,RT-4668,ACREVIS,NAlog Output 8 Channels, 0~5V, 15Bit
CREVIS,RT-4664,ACREVIS,NAlog Output 4 Channels, 0~5V, 15Bit
CREVIS,RT-4648,ACREVIS,NAlog Output 8 Channels, 0~5V, 14Bit
CREVIS,RT-4644,ACREVIS,NAlog Output 4 Channels, 0~5V, 14Bit
CREVIS,RT-4628,ACREVIS,NAlog Output 8 Channels, 0~5V, 12Bit
CREVIS,RT-4624,ACREVIS,NAlog Output 4 Channels, 0~5V, 12Bit
凸出式插拔式結(jié)構(gòu),嵌入式插拔結(jié)構(gòu),導軌式結(jié)構(gòu)等,并有的塑料外罩(導軌式為式),用進行整定。當被測量的交流電壓經(jīng)隔離變壓器降壓后與被測電壓成正比的電壓Ui,經(jīng)整定后進行整流,整流后脈沖電壓經(jīng)濾波器濾波,與Ui成正比的直流電壓Uo,在電平檢測中Uo與直流參考電壓Ue進行比較,若直流電壓Uo高于參考電壓,電平檢測器輸出正,驅(qū)動出口繼電器,則本繼電器處于狀態(tài)。反之,不論是過電壓繼電器或是低電壓繼電器,若直流電壓Uo低于參考電壓Ue,電平檢測器輸出負,本繼電器處于不狀態(tài)。2.主要技術(shù)參數(shù)輔助電源:AC/DC85-265V過載能力:交流回路允許長期接通1.2倍額定值。無自爆,耐火或阻燃產(chǎn)品。9)立桿及其主要構(gòu)件的所有外露金屬表面均應采用熱浸鍍鋅層防護,鍍鋅層均勻且厚度不小于55μm。10)立桿及其主要構(gòu)件結(jié)構(gòu)裝配的應下列要求:11)立桿及其主要構(gòu)件高度允許偏差±200mm;12)立桿及其主要構(gòu)件截面尺寸允許偏差±3mm;13)立桿及其主要構(gòu)件安裝后塔軸線位移允許偏差±5mm;14)立桿及其主要構(gòu)件垂直允許偏差為塔身高度的1/1000;15)立桿及其主要構(gòu)件尺寸應協(xié)調(diào)一致,桁架塔塔身應對燈架升降起到良好的導向、定位作用。16)鋼結(jié)構(gòu)的聯(lián)接螺栓應簡單統(tǒng)一,螺栓規(guī)格宜采用M16,連結(jié)應有防松動措施,且牢固可靠。17)立桿及其主要構(gòu)件所有焊接處焊縫應符合要求。