Specifications for LQ-401CL
Specifications LQ-401 CL
Camera Link Interface
Pin Signal Function
1 14 GND
2 15 Xo-/Xo+ CL Data
3 16 X1-/X1+ CL Data
4 17 X2-/X2+ CL Data
5 18 Xclk-/Xclk+ CL Clk
6 19 X3-/X3+ CL Data
7 20 SerTC+/SerTC- Serial in *
8 21 SerTFG-/SerTFG+ Serial out *
9 22 CC1-/CC1+ Trigger *
10 23 CC2-/CC2+ Reserved
11 24 CC3-/CC3+ Not used
12 25 CC4-/CC4+ Not used
13 26 GND
*) In Camera Link or 12 pin Hirose
Note:
Camera Link base configuration shown.
For medium configuration refer to Camera
Link specifications or operation manual.
HIROSE HR10A-10R-12PB-71
DC In / Trigger
Connection Pin-out
Pin 1 Ground
2 +12V to +24V DC
3 Ground
4 Reserved
5 Ground
6 RXD RS 232C*
7 TXD RS 232C*
8 Ground
9 XEEN output
10 Trigger input (TTL)*
11 DC in +12V to +24V
12 Ground
Dimensions
Ordering Information
Front view
Side view
Bottom view
Rear view
Spectral Response
Scanning system Line sensor with internal clock
Pixel clock 84.00 MHz
Line rate Standard
Programmable
54.79μs (Full resolution/binning/internal trigger)
54.79μs~14.30ms, 11.9ns increments
Sensor 4 CMOS line sensors
mounted on R/G/B/NIR beam splitter prism
Sensor scanning width 28.672 mm
Cell size 7 μm x 7 μm
Active pixels 4 x 4096 (h)
4 x 2048 (h) with 2:1 binning
Sensor sensitivity Radiometric: 64nJ/cm2
Sensitivity 2800 Lux (7800K, gain=low,
shutter=OFF, 100% video)
S/N ratio 55 dB on green with gain = 0 dB
Video output 4 x 8 bit in CL base configuration
4 x 10 bit in CL medium configuration
Gain Master tracking
Individual mode
Master: 0 dB to +8 dB
R/B: –4 dB to +6 dB
Analog gain= Low (0dB) or High (+6dB)
R/G/B: –4 dB to +14 dB
Analog gain= Low (0dB) or High (+6dB)
White balance Manual, fixed or one-push
Adjustable range 4000 K to 9000 K
Fixed: 4000 K, 4600 K or 5600 K
Shading correction Individual R/G/B/NIR flat or R/B/NIR to G
Flat-field correction PRNU Correction: Built-in
DSNU Correction: Built-in
Synchronization Internal X-tal or external trigger
Trigger modes No-shutter, shutter-select and pulse width control
Programmable exposure 9.52 μs to 14.2 msec. in 11.9 ns increments
Functions controlled by
RS 232C or CL
Trigger modes, scan rate, exposure time, gain/
black level, shading correction,
flat-field correction, white balance,
knee-function, diagnostics
Diagnostics Test pattern generator. (Color bar, gray pattern
and white) LED for power
Lens mount M-52 mount. (Standard)
Nikon F-mount. (Factory option)
Sensor alignment Better than ±0.1 pixel (at center)
Operating temperature -5°C to +45°C/20 – 80% non-condensing
Storage temp./humidity -25°C to +60°C/20 – 80% non-condensing
Vibration 3G (20Hz to 200Hz, XYZ direction)
Shock 50G
Regulations
Emission: CE CISPR Pub. 22 (EN55022)
Immunity: CISPR Pub. 24
IEC61000-4-2 Conforming level 4
FCC Part15 Class B
RoHS
Power 12V DC to 24V DC ± 10%.
Dimensions (H x W x D) 90 mm x 90 mm x 120 mm
(without connector and lens mount protrusion)
Weight 1050 g
LQ-401 CL-M52 4 CMOS RGB/NIR Line Scan Camera. P-mount (M52)
LQ-401 CL -F 4 CMOS RGB/NIR Line Scan Camera. F-mount
70
60
90
90
4-M4
depth5
5 90
5 90
60 60 45
4-M4
depth5
4-M4
depth5
11 120 6.3
DIGITAL I / O
- 1
DIGITAL I / O
- 2
POWER /
TRIG
W.B.
DC IN
TRIG
SW1
U4-40:Fixed screw
M52 Mount
φ74
70
60
90
90
4-M4
depth5
5 90
5 90
60 60 45
4-M4
depth5
4-M4
depth5
11 120 6.3
DIGITAL I / O
- 1
DIGITAL I / O
- 2
POWER /
TRIG
W.B.
DC IN
TRIG
SW1
U4-40:Fixed screw
M52 Mount
φ74
70
60
90
90
4-M4
depth5
5 90
5 90
60 60 45
4-M4
depth5
4-M4
depth5
11 120 6.3